問題一覧
1
stairs can either be
open,closed,supporting or supported
2
On a close stair layout is done on the
Stairwell wall
3
Treads on exterior stairs should be slightly
Sloped to allow for drainage
4
What is the perpendicular distance between throat and soffit lines?
effective depth
5
Verify Blueprint measurements by taking
A Field measurement
6
Stepping off, should be limited to
Six risers
7
Reinforcing steel should be installed before
Riser forms
8
The maximum vertical distance between landings is
3700mm
9
The 7-Eleven rule is
Unit rise times 11÷7
10
The maximum unit rise of a public stair
180
11
The minimum tread depth for a public use stare
280mm
12
Additional support for a residential precast stair is required when stairs is more than
5 risers
13
When a mid height landing is installed the number of risers above and below the landing are
equal
14
What is measurement from finished floor to finished floor below ?
total rise
15
What surface is required for all public use stairs
non slip
16
Riser should be bevelled at
30-40 degrees
17
The concrete compartment that house is a stair is known as
stairwell
18
The Layout rod must be long enough to extend from the
nosing to bottom riser (nosing to nosing)
19
The minimum headroom for public use stairs
2050mm
20
Stringers and cleats should be placed how far above the treads
30mm
21
When pouring stairs, concrete placement should begin at
The bottom of the stairs
22
What is the maximum unit run for public stairs?
none
23
What is the private maximum run?
355
24
What is your maximum nosing projection?
25mm
25
What is the temporary structure installed to support concrete or Masonary construction?
falsework
26
Measures must be taken at all construction sites to prevent anyone from being exposed to
undue risk
27
A covered walkway is required when the construction activity is
Less than 2 m from public walkway
28
Temporary work platforms require a guard rail when they are
3 m above ground
29
The minimum time required to maintain a firewatch after welding is
One hour
30
Excavations deeper than 1.5 m must be.
Cut back or shored
31
An engineer must design all shoring for excavations of
3 m or more
32
Solid barricades on the edge of fly forms are there to
Prevent people from lookin and dropping tools
33
Underpinning provides what type of support
Permanent support
34
What piece on a cable clamp is always installed on the dead end of the rope
u bolt
35
What should be set up on working above rebar?
fall protection
36
How far must you stay away from powerlines in heavy equpiment?
7m
37
What signal means stop moving the load?
swinging one arm to the side
38
outrigger pads must be
suitable size and on solid ground
39
hand rail heights
920-1070
40
slings should not have an angle more than?
30 degrees
41
spoil piles must be at least how far from excavations?
1m
42
using beams and columns to shore a structure before excavation is?
needling
43
Any job site incident must be
Reported to supervisor immediately
44
The horizontal distance between standards in each direction
bay
45
The vertical distance between Transoms
lift
46
Acts as a footing to distribute the load
mudsill
47
The member that is there to support scaffold planks
ledger
48
Guard rails are required on platforms at what height
3m
49
Toe boards must be installed on all scaffold platform is more than
3.5m above work or public area
50
The maximum height to width ratio of a freestanding scaffold is
3:1
51
The maximum space of scaffold ties is (vertically)
4.6
52
The maximum space for scaffold ties (horizontally)
6.4
53
The maximum uniformly distributed load on the light duty scaffold is
122kg
54
The maximum, uniformly distributed load on a heavy duty scaffold is
122-367kg
55
The maximum plank span for a light duty scaffold is
3m
56
The maximum plank span for a heavy duty scaffold is
2.3m
57
How far should mudsills project be on the centre of the standard
150-225mm
58
Bracket scaffolds can only be used as what type of scaffolds
light duty
59
Ladder, jack scaffolds can not be more than?
5m
60
When assembling frame scaffold on a slope, start the assembly, where
high side
61
What is used with a tube and coupler scaffold to increase the capacity of a connection
check clamp
62
What is considered a negative tie
reveal tie
63
Scaffolds are designed with a factor of safety at
4:1
64
What systems are used when it’s not practical to use frames?
modular
65
When workers are travelling on a rolling scaffold, they cannot be higher than
2x smaller base dimension
66
What must be installed at all times, when erecting or working from a swing stage?
Fall arrest
67
How far must wood planks extend between Transoms?
150-300