問題一覧
1
Vertical support of _____ is placed each storey or maximum 3 meters on center
copper tubing
2
CPVC: maximum temperature rating is______
180 deg. F
3
Copper tube for water supply piping shall have a weight of not less than _____.
type L
4
Trap arm size of a laundry tub
38 mm
5
The Old Fire Code of the Philippines
PD 1185
6
What is the accreditation number of NAMPAP?
14
7
An adjustable tubing connection, consisting of a compression nut, a friction ring, and a compression washer, designed to fit a threaded adapter fitting or a standard taper pipe thread
slip joint
8
The Administrative Authority must be notified at least ___ working days before such inspection is intended
3
9
Integrated within an air accumulator vessel which is designed to discharge a predetermined quantity of water into fixtures for flushing purposes
flushometer tank
10
Distance of bottom of all pipe tranches to the footing of any adjacent building or structure parallel to it
45 degrees
11
Philippine Clean Air Act
RA 8749
12
An open return bend usually made up of two 90° bends
return bend
13
the reconstruction or renewal of any part of an existing building for its maintenance
repair
14
trap arm size of wash basin (lavatory) single, dental units or cuspidor
32 mm
15
protection from breakage for piping passing under or through walls
embedded metal pipe sleeves
16
Distance of water closet or bidet center to side
0.375 m
17
Vertical support of _____ is placed not less than every other storey height
screwed pipe
18
What will happen if a drainage piping is placed at slope of 10mm/m due to structural conditions?
decrease in dfu loading
19
The 2008 Fire Code of the Philippines
RA 9514
20
for IPS piping 25 mm and larger, support intervals shall be ___
3.6 m
21
Every building where _____ shall have a sewer service connection to a public or private sewer systems
plumbing fixtures are installed
22
Caulked-on closet rings or closet flanges shall not be less than ____
6.4 mm thick
23
Vertical support of _____ is placed every 1 meter
plastic pipe
24
Which authority is responsible for the administration and enforcement of the National Plumbing Code?
plumbing official
25
in-charge of the enforcement and implementation of RA 1378 and its IRR.
Professional Regulatory Board for Master Plumbers
26
Fire Code of the Philippines
RA 9514
27
A hose connection with two-gated outlets permitting two connections of the same or smaller coupling diameter to be taken from a single supply line
wye
28
Any change, addition or modification in construction or occupancy
alteration
29
The birth of the plumbing profession in the Philippines is traced back to the ___ century.
17th
30
Common maximum service temperature rating of PVC
140 deg. F
31
Wiped lead joints shall have an exposed surface on each side of a joint not less than _____
19 mm
32
trap arm size of water closet
76 mm
33
Who is the current chairman of the Board of Examiners for Master Plumber?
Reynald B. Ilagan
34
A device with discharges a predetermined quantity of water into fixtures for flushing purposes and is actuated by direct water pressure
flushometer valve
35
ASTM means?
American Society for Testing and Materials
36
What section of RA 1378 enumerates the qualification for persons applying for examination?
section 12
37
Preferred when a piece of pipe needed is shorter than 150 cm long
double hub
38
used for a well-fitted hub and spigot connections
standard pipe
39
IPS shall be supported at ___ intervals for piping 19 mm diameter and smaller
3 m
40
Color for Type M copper pipe
red
41
A tank located above or integral with water close3t, urinal, or similar fixtures for flushing or removing excrements in the fixture
flush tank
42
Distance of urinal to side wall center to side
0.3 m
43
The top edge of a receptacle from where water overflows
flood level rim
44
A plumbing permit shall become null and void if the plumbing work has been suspended or abandoned for a period or _____
120 days
45
trap arm size of floor drains, grease interceptors, showers, etc.
51 mm
46
recommended when the length of a pipe needed is more than 150 cm long wherein cutting is not necessary
single hub
47
This examination subject in Master Plumbing was originally split into two
practical problems
48
1 fixture unit is equal to?
1 cu. ft per minute
49
for pipes directly embedded in concrete and masonry walls
metal sleeve
50
(ANSI) Pipe Color code for Fire Quenching
red with white lettering
51
Minimum weight of a lead for flashing or vent terminals
14.63 kg per sqm
52
The distance of water closet or bidet center to center
0.75 m
53
A device located at the bottom of the tank for the purpose of flushing water closet and similar fixtures
flush valve
54
What is not included in a plumbing unit? - kitchen sink - urinal - laundry tray - hose bibb
urinal
55
Date of the Accreditation of NAMPAP
October 2, 1975
56
For caulked-on closet ring, the minimum overall depth shall be
2"
57
Creation of Professional Regulation Commission
PD 223
58
Depth of the molten pig lead in a caulked joint
25.4 mm
59
A pipe or conduit for carrying sewage and wastewater
sewer
60
a water heater is classified as?
plumbing appliance
61
National Building Code of the Philippines
PD 1096
62
Voids between pipes and sleeves through concrete floors in the ground shall be appropriately sealed with _____.
bitumen
63
The Plumbing Code has been in existence for almost _____ since its promulgation before it has been amended
40 years
64
Vertical support of _____ is placed every storey or closer
cast iron soil pipe and b&s hubless pipe
65
In a plumbing unit, how many floor drains are included?
3
66
Copper tubing shall be fully externally protected with a/an _____ and fiberglass wrapping installed inside a split rigid casing whenever installed underground.
bitumastic coating
67
Code on Sanitation of the Philippines
PD 856
68
a registered master plumber must not supplant another Registered Master Plumber after definite steps have already been taken toward his/her being commissioned to perform the contract
code of ethics no. 2
69
(ANSI/ASME) Pipe Color code for Toxic or Corrosive liquids, acids (Nitric Acid)
orange with black lettering
70
Philippine Mechanical Engineering Act of 1998
RA 8495
71
used in lieu of the single hub to do away with caulking of joints
hubless pipe
72
protection from external corrosion for pipes passing through or under cinders or other corrosive materials
polyethylene sheath
73
The year when NAMPAP was organized and registered with the Securities and Exchange Commission
1935
74
Each fixture directly connected to the drainage system shall be equipped with a _____
water-sealed trap
75
Distance or urinal to urinal center to center
0.6 m
76
Each member of the board, shall at the time of his appointment be at least _____ of age
30
77
A pipe flange that is not drilled for bolt holes
blank flange
78
Tube made of plastic material and colored black. The cross-sectional shape is normally oval and is denoted by its outside diameter or 0.D.
polybutylene
79
All plumbing plans, drawings, diagrams, etc. shall be submitted in ___ sets for permit application
6
80
Elastomeric gasketed and rubber-ring joints shall comply with _____ installation standard
IAPMO