問題一覧
1
A unique non-changeable number set at the factory identifies each radio
HHRID
2
transmissions are automatically tag with identification number and encrypted using ___ Unique to each radio
TEK
3
the ___ Along with a callsign, enables the rescue center to collect isolated personal report data and other vital background information for the isolated personnel
CSEL Group identification code (CGI)
4
Referred to as the mission key
Pass phrase
5
to use the ___ Communication must be initiated by the rescue Forces an accepted by the radio operator
default key
6
the CSEL is able to maintain volatile memory for ___ once the capacitor is fully charged
10-20 minutes
7
Will result in zeroization of primary TEK, GPS keys, waypoints, all free text messages and
stage one
8
allows a user to continue to use the radio
stage one zeroization
9
password entry attempts are allowed each time the radio is turned on. After ___ Failed password attempts a state zeroization is performed on the radio is powered down
3
10
The radio is powered by a main battery pack, when new and under nominal operating conditions, provides approximately __ hours of operation
96
11
and extended mission mode provides memory retention and low accuracy clock for GPS acquisition for approximately ___ days
120
12
what is the color of the cells for LPU-9
sea blue
13
for life raft storage the shelves should be ___ from the wall and __ from the floor
4 in, 12 in
14
at the ___ inspection cycle, life rafts shall be subject to a functional test
fourth
15
low profile life raft without a canopy
LRU-17
16
this life raft contains ballast bags/water pocket, inflation floor and canopy
LRU-16
17
The inside panel of the ___ Canopy is orange/blue
LRU-16
18
this life raft has an orange spray shield with a small viewing port
LRU-23
19
torque coupling nut on LRU-16 to a value of ___
50-60 in pounds
20
the ___ Flotation assembly outer wall is constructed of urethane coated nylon
LRU-9
21
a ____ On Flotation equipment in service or in storage I’ll be perform for mildew whenever weather or other conditions warrant
Special inspection
22
all Flotation equipment received from supply shall have a ___ Prior to performing any other type of inspection
screening inspection
23
_____ Shall consist of a screening and periodic inspection and a functional test and shall be performed on all Flotation equipment receipt from supply, another activity or from the manufacture
initial Installation inspection
24
Cylinders having an outside diameter of 2 inches or less in a length of less than 2 feet are exempt from hydrostatic test
true
25
flotation equipment which fails to meet inspection criteria shall be condemned in accordance with ___
23-101
26
all flotation equipment utilized for training purposes should be marked “ for training only “ in ___ for life rafts and ___ for life preservers
1 in, 1/2 in
27
Do unit may authorize the installation/location of additional survival items and accessories through their operational instructions and supplements
true
28
Life preserver data
Form 466
29
preposition life-support flight equipment
Form 46
30
MA-1 and MA-2 sea rescue cat
Form 339
31
Survival kit record
Form 338
32
Life raft/container inspection
Form 337
33
Life preserver inspection record
Form 336
34
Notice certification avoid when seal is broken
Form 255
35
at the Third inspection cycle, life for us shall be subject to a functional test, except the LRU-1 and F-2b liferafts
false
36
Will be functionally tested only when the attached inflation assembly is due a hydrostatic test
LRU-1 and F-2B
37
Measures 22” x 6” and is constructed of .125 inch mild steel
jig
38
LPU cell protector Will be Fabricated from condemned life preserver material
true
39
Weighs 3.9 pounds and provides a minimum of 60 pounds buoyancy
LPU-38
40
The LPU-38 is not for use and aircraft which do not have ejection seat systems
true
41
all equipment utilized for training purposes should be marked “ for training use only “ in ___ For life preservers
1/2 in
42
If there is any duplication/repetition of information noted on equipment/procedures within Flotation technical orders submit
Form 22
43
is equippped with FLU-9autonatic/manual inflation assembly
LPU-38
44
the LPU-38 automatic inflation assembly may be operated in the manual mode an unlimited number of times without affecting the one time automatic capability
true
45
the LPU-38 automatic inflation is a backup to the manual inflation
true
46
when the LPU-38 is being used temporarily the adjustment straps should be secured with the elastic keepers or two turns of masking tape
true
47
preferred method of detecting leaks
soap water
48
all markings in CO2 cylinders of ___ in height will be bad scribed using permanent pigmented waterproof ink pen
1/8 in
49
the threaded portion of the CO2 cylinder neck shall contain a minimum of ___ full threads
7
50
life preserver shall fully inflate to design shape, without evidence of restriction in less than __
30 seconds
51
leakage test can be performed with carbon dioxide gas in life preserver
false
52
damage may occur to oral inflation valve if air supply pressure entering life preserver exceeds ___
10 psi
53
when performing LPU-38 leakage test inflate bladder to proper pressure of ___ PSI
3.25 pounds force per
54
after inflating LPU-38 to 3.25 pounds force per PsI allow to stabilize for a minimum of ___
15 minutes
55
when leak testing LPU-38 after a minimum of 1 hour bladder pressure should not decrease to less than ___, for a max pressure of 3.25 psi
2.5 psi
56
when cleaning LPU prepare solution of detergent consisting of __ of detergent per gallon of water
1/4 to 1/2 ounces
57
once LPU-38 is inspected the date and activity performing the inspection and testing will be stenciled or stamped using ____ waterproof ink
black
58
when stenciling on the bladder of the LPU-38 lettering shall be no less than __ and no more than ___ in height
1/8 in, 1/4 in
59
for LPU-38 verify automatic inflator battery voltage is ___ volts direct current or greater
12.0
60
on the LPU-38 cover plate in position and secure Philips head screws, torque cover plate to ___ in pounds
12+-1
61
for LPU-38 place cover plate in position and secure Allen head screws, torque to ___ in pounds
6+-1
62
on the LPU – 38 attach the cylindrical pull handle lanyard to the inflator level using a ___
Larks head not
63
for the LPU – 38 place cap nut on left hand manifold valve and torque cap nut to manifold valve to ___ in pounds
12
64
for the LPU-38 top side folding procedures, full top edge down to form a fold approximately ___ in wide
3
65
on the LPU – 38 when closing the exterior covers stop zipping approximately____ Inches from the bottom right
3-4
66
on the LPU-38 when installing make aside release buckle torque screw to ___ in pounds
12-15
67
on the LPU-38 when installing the female realize buckle torque screws to ___ in pounds
12-15
68
the CSELs gaining unit will register the radios into the JSETS database before issuing
true
69
check ___ to ensure the radio holds two or three segments of GPS keys
monthly
70
check at least every __ months or so to ensure the CSEL has valid TEK
6
71
zeroize CSEL before shipping back for repairs
true
72
torque CSEL antenna screw to __ in oz
40+-4
73
a CSEL non rechargeable battery with less than __ will be removed from service
80%
74
all CSEL batteries are marked will a manufacture stat code in the format ___
MMYY
75
a portable universal battery charger use for rapid charging of various types of field equipment batteries
PP-8498/U (SPC)
76
preferred adapter to interface all models of the CSEL rechargeable battery to the SPC
BTA-70581A
77
when charging CSEL batteries the LED light will___ when done
stop blinking
78
ensure CSEL batteries are fully charged every __ months
12
79
rechargeable CsEL batteries lose about __ capacity per month when stored at room temperature
6%
80
no rechargeable batteries retain approximately __ capacity after 5 years at room temperature
95%
81
LPU-38 TO
14S-1-102-31
82
tack through elastic keepers of LPU-38 using one turn, double waxed __
8/4
83
two independent inflatable assemblies(bladders), each with an inflation assembly. The bladders are packed inside a black cloth inflation shell assembly. two straps adjusted by a buckle, which snaps around the wearers chest to keep in position when worn
LPU-38
84
FLU-9 TO
11P10-6-7
85
LPU-38 TO
14S-1-102-31
86
LRU-1/, F-2B, 25 man life rafts, LPU-3, LPU-6, LPU-10 TO
14S-1-102-21