  • 1

    a solar heated system used to temper or heat the hot water system shall be by the use of a double walled heat exchanger

    false

  • 2

    the size of the drainage piping shall not be reduced in the direction of flow

    true

  • 3

    a globe valve has very little resistance to flow

    false

  • 4

    a compression joint is also known as a flare joint

    false

  • 5

    a grease interceptor installed on the same floor as the fixture shall have one half the liquid holding capacity of the fixture

    true

  • 6

    the requirement for all soldered joints to be properly fluxed (lead Free) and made with approved lead free solder applies to water lines but not drains, waste and vents lines

    false

  • 7

    separate facilities for men and women are required when the restrooms for the public are required (building with occupancy of 100 perons)

    true

  • 8

    atmospheric vacuum breakers shall be installed with the critical level above the flood level rim of the fixture they serve, and on the discharge side of the last control valve of the fixture. no shutoff valve or faucet shall be installed beyond the vacuum breaker.

    true

  • 9

    2 7/8 subtracted from from 7 3/4 is 4 7/8

    true

  • 10

    a 1/2'' I.D new copper pipe will deliver as much water as a new 3/4'' galvanized steel pipe of the same length if operating at the same pressure

    false

  • 11

    reverse flow in a water supply system, caused by a vacuum is called back siphonage

    true

  • 12

    three floor mounted water closets may be connected to a horizontal 3'' fixture branch wether flush tank or flush valve type

    false

  • 13

    hubless cast iron soil pipe coupling are properly installed by tightning the band screws as much as possible

    false

  • 14

    the intermingled use of different types of pipe and fittings for water service does not affect the rate of material deterioration?

    false

  • 15

    one fixture unit equals 8.5 gpm

    false

  • 16

    a vent pipe mut extend above the roof at least a minimum of 12 inches

    true

  • 17

    the small hole at the top end of the dip tube in a domestic water heater serves as a

    siphon breaker

  • 18

    where is the corporation stop located in the water service line

    at the tap in the water main

  • 19

    if the rate of flow is doubled in any given size water pipe the pressure loss will be?

    increased about 4 times

  • 20

    which of the following is the definition of "water service pipe"

    the pipe from the water main to the building

  • 21

    a peppermint test is used for testing

    the drainage system

  • 22

    what is the average depth of a graded ditch which is 9'-6" at one end and 3'-4" deep at the other end?

    6.5

  • 23

    a waste pipe that discharges into and through a proper open connection is called

    indirect waste line

  • 24

    which style water closet holds the least amount of water in its trap

    flush down

  • 25

    a relief vent shall be connected to the vent stack above the rim of the fixture at least

    6 inches

  • 26

    unions shall be installed on all large water heaters within one of the following distance

    5 feet

  • 27

    the device known as the ___________ controls the water temperature maintained in a hot water tank for a single family use

    thermostat

  • 28

    faucet washers requiring replacement ina kitchen sink faucet may indicate wear of the faucet

    seat

  • 29

    the tube attached to the ballcock and discharging into the overflow of a toilet tank is designed to

    replenish the water seal of the bowl trap

  • 30

    the vertical distance between a fixture outlet and a trap weir shall be as short as practicable but in no case shall the tailpiece from any fixture exceed

    24 inches

  • 31

    the illinios plumbing license law requires a licensed plumber for

    replacing plumbing fixtures

  • 32

    a pipe makes an angle of 30 degrees from the vertical is considered

    vertical

  • 33

    the minimum size of any building drain or building sewer shall be determined on the basis of

    total drainage fixture units

  • 34

    the plumbing inspection of a plumbing system prior to covering walls and floors is called a

    rough in inspection

  • 35

    the minimum size trap for a shower is

    2 inches

  • 36

    the maximum temperature of water discharging into any part of the plumbing drainage

    180 degrees