  • 1

    The EPA's definition of a "small appliance" includes _____

    products that are manufactured, fully charged, and hermetically sealed in a factory

  • 2

    _____ is/are approved for retrofit into existing household refrigerators.

    No hydrocarbons

  • 3

    Recovery equipment used during the maintenance, service, or repair of small appliances must be certified by a(n) _____-approved laboratory.

    EPA

  • 4

    Refrigerant recovery devices must be equipped with low-loss fittings, which are fittings that are used to connect the recovery device to an appliance and that _____.

    prevent loss of refrigerant from connections

  • 5

    A(n)_____is not a Type I appliance.

    MVAC-like system that holds 2.5 lb of R-12

  • 6

    The maximum allowable factory charge of refrigerant for Type I appliances using system dependent recovery equipment is _____ Ib.

    15

  • 7

    Any technician that opens an appliance for maintenance, service, or repair must have at least one self-contained recovery machine available at their place of business, except when recovering refrigerant passively from _____ appliances.

    small

  • 8

    _____ is highly pressurized and generally does not need to be recovered.

    R-744

  • 9

    If refrigerant in a recovery cylinder is suspected of being contaminated , then _____

    take a pressure reading of the cylinder

  • 10

    Following the recovery of R-410A from an appliance, it _____.

    should be recovered into a recovery vessel that is clearly marked to ensure that mixing of refrigerants does not occur

  • 11

    Standard vacuum pumps that are designed specifically for evacuation and dehydration can _____.

    never be used as a recovery device in combination with a pressurized container

  • 12

    During refrigerant recovery, it is necessary to take measures to help release trapped CFC, HCFC, or HFC refrigerants from the compressor oil when _____.

    using passive recovery devices on small appliances with non-operating compressors

  • 13

    A storage cylinder of R-404A that is stored at 80°F and does not contain any non-condensable impurities would have an approximate pressure of ____ psig.

    174

  • 14

    Refrigerant _____ measurement is an acceptable method to monitor the 80% fill level in a recovery tank.

    scale or tank internal float device

  • 15

    _____ can be mixed in an appliance.

    No refrigerants

  • 16

    CFC and HCFC refrigerants can decompose into _____ acids at high temperatures.

    hydrochloric and hydrofluoric

  • 17

    CFC and HCFC refrigerants can decompose into _____ gas at high temperatures.

    phosgene

  • 18

    _____ is an approved refrigerant for new household refrigerators, freezers, and combination refrigerators/freezers.

    R-600a

  • 19

    A recovery device used with small appliances containing CFCs, HCFCs, and HFCs must recover_____ % of the refrigerant when the compressor is operating or achieve a 4" vacuum.

    90

  • 20

    New household refrigerators may not be factory charged with ______.

    R-450A

  • 21

    _____ is required when attaching a gauge set to check the system pressure.

    Having manual or self-sealing valves on the end of a gauge set hose to minimize any accidental refrigerant release

  • 22

    If refrigerant is vented off the top when filling a charging cylinder, it _____

    must be recovered if it is a CFC, HCFC, or HFC

  • 23

    A technician should be attentive to signs of contamination in the oil when recovering refrigerant from a system that suffered a compressor burnout because the _____

    system will have to be flushed if contaminants are present

  • 24

    Permanent safety markings are not required _____ of household refrigerators.

    on the exterior

  • 25

    _____ can be used as a direct service "drop-in" substitute for R-22.

    No refrigerant