  • 1

    There are sheet metal troughs with hinged or removable covers for housing and protecting electrical wires and cables and in which conductors are laid in place.

    Wire ways

  • 2

    Most of the required electrical parameters apply to an incandescent bulb are

    Rated power and rated voltage

  • 3

    When tightening a terminal screw connection, the end of the wire should pass around the screw in the same direction as the screw is turned so that

    the wire will not turn off

  • 4

    A part providing an appropriate degree protection of equipment against contains external influences and defined degree of protection again contacts with live parts any direction.

    Enclosure

  • 5

    Locknut, bushing and connectors are called electrical_

    Fittings

  • 6

    Why is if necessary to use torque wrench in tightening bottled joints of copper bus bars inside bus ducts and bus ways?

    To make sure the joints are well tightened

  • 7

    What is the commonly used conduit in Service Entrance?

    RSC/RMC

  • 8

    What is the types of fitting commonly used for exposed conduit support?

    Conduit strap/Clamp

  • 9

    When raceways are exposed to widely different temperatures it should be

    Sealed

  • 10

    When raceways are exposed to widely different temperatures it should

    Sealed

  • 11

    Before adding to or altering an installation, you must ensure that_

    Safety precautions are followed

  • 12

    What will you do if the load schedule reflects a 20AT/2.0 sq.mm. Lighting Branc of hwhich breaker is over rated?

    Look for the wiring layout and check groupings.

  • 13

    The size of circuit breaker to be used in 40 A motor full load current is

    100 AT

  • 14

    The selection requirements for circuit breaker are

    Kilo Ampere Interrupting Capacity, Ampere Trip and Ampere Frame

  • 15

    When measuring load current, the ammeter is connected

    In series with the load

  • 16

    The material used in long length bus or lie to give alowance for thermal expansion is

    Flexible braided copper plates

  • 17

    The current is directly proportional to the voltage and inversely proportional to resistance.

    Ohm's Law

  • 18

    Before adding to or altering an installation, you must ensure that

    Safety precaution are followed

  • 19

    What amount of current will be drawn by incandescent bulb connected to a 115-volt circuit if its resistance is 264.5 ohms?

    0.43 amps.

  • 20

    Before adding to or altering an installation, you must ensure that

    Safety precaution are followed

  • 21

    When measuring ballast resistance if it is defective o good, it is necessary that the source.

    de-energized

  • 22

    A circuit breaker is an electrical protective device which

    Protects electrical equipment from current surges and on

  • 23

    The 24 hours protection from home and commercial building to monitor and access the video any time anywhere on this device.

    CCTV Camera

  • 24

    The Auxiliary device of CCTV that monitor the motion daily.

    Camera

  • 25

    A part Auxiliary device that capture live events and save as video files

    Recorder

  • 26

    The minimum size of conduit commonly used in laying-out of Auxiliary Devices

    ¾" diameter

  • 27

    An electricians should always have his tools in good working condition, the most important reason being is.

    Defective tools can cause accidents or damage to equipment

  • 28

    What type of hand tools commonly used in boring of ½" diameter hole in panel board

    Knock out Puncher and Adjustable Wrench

  • 29

    It is the connection between the grounded circuit conductor and the equipment grounding conductor at the service.

    Grounding electrode conductor

  • 30

    What is the fitting commonly used for tightening between the boxes the RSC conduit?

    Straight Connector

  • 31

    Part of the Auxiliary System that set the motion-trigger action individually for each camera.

    Motion detection

  • 32

    A kind of diagram that is used in designing or troubleshooting electrical installation control equipment so arranged to facilitate the tracing of the circuit.

    Schematic diagram

  • 33

    One most advantage of using rubber insulation tape in splice is

    All of the above

  • 34

    The box use for convenience outlet is

    Utility Box

  • 35

    A mechanical connector that is crimped unto a conductor for both splice and termination is known as

    Split bolt connector

  • 36

    Commonly used adhesive materials for joining of PVC conduit

    PVC Solvent

  • 37

    A live duplex wire can be de-energized quickly and safely by cutting

    One-by - one using diagonal cutter

  • 38

    When measuring load current, an ammeter is connected

    In series with the load

  • 39

    When measuring load resistance, the ohmmeter is connected_

    Parallel with the source

  • 40

    What is the Ampacity of #8.0 sq.mm. THW wires?

    50 amperes

  • 41

    Wnicn or the rollowing is an output aevice

    Emergency Break Glass

  • 42

    The technical term for the type THW wires mostly is industrial wirings is

    Moisture and Heat resistant thermoplastic

  • 43

    Which of the following is the input device

    All of the above

  • 44

    When skinning a small wire, the insulation should be " pencil down" rather that cut squire to

    Decrease danger of nicking the wire

  • 45

    A diagram that shows the location and actual termination of auxiliary devices called

    Wiring diagram

  • 46

    Who is the father of the electricity?

    Dr. William Gilbert

  • 47

    One objectives of preventive maintenance is

    to keep the machines in good condition

  • 48

    When circuit breaker is always tripping, most likely

    there is an over current

  • 49

    In climbing ladder, you must position the ladder

    30° from the vertical

  • 50

    What is the practical unit of electrical energy?

    KWHr

  • 51

    The actual power consumed in electrical system is expressed in

    KiloWatt - hour(KW- Hr)

  • 52

    An electrician should consider all equipments live unless he definitely knows that they are not. The main reason of this practice is to avoid

    personal injury

  • 53

    What is the minimum bending radius applied to ½", ¾" and 1"?

    5 inches

  • 54

    A motor with rated full load current of 100 amperes can be wired with cable rated

    250% × 100 Amps

  • 55

    Personal Protective Equipment (PPE) helps

    to reduce injuries

  • 56

    Before starting any installation work, alteration, repair of extension on any electrical system, what type of permit is needed?

    Electrical permit

  • 57

    The reason for grounding the frame of a portable electric hand tools is to:

    prevent the frame of the tool from becoming alive-to-ground

  • 58

    What rating shall have a feeder conductor in relation to its protective device when used to general purpose?

    equal or greater than protection rating

  • 59

    What is the PEC requirement on standard height for outlet?

    1 foot, 30 cm, 300 mm

  • 60

    How many marking should a rigid non-metallic conduit have?

    1

  • 61

    What type of switch is used to control one lamp from two locations?

    three-way switch

  • 62

    What device is used for testing an armature for short circuit coils?

    growler

  • 63

    A measuring instruments used by electricians and refrigeration mechanics for measuring de current, dc/ac voltage and dc resistance/continuity.

    Multimeter

  • 64

    To rescue an electric shock victim, the first thing to do is to lift away live wires with

    nonconductive materials

  • 65

    What is the maximum spacing allowed for convenience outlet in continuous wall?

    3.6 meters

  • 66

    What is the standard voltage in the Philippines?

    220V and 60Hz

  • 67

    What is the standard height of light switches?

    1.20 meters above finish floor according to PEC

  • 68

    What is the standard height of panel board?

    1.50 meters above finish floor according to PEC

  • 69

    A point in the wiring system at which current is taken to supply the utilizatic equipment is called

    Convenience outlet

  • 70

    What is the ampacity of # 5.5 sq. mm. stranded wires?

    30 A

  • 71

    What is the ampacity of # 3.5 sq. mm. stranded wires?

    25A

  • 72

    What is the ampacity of # 2.0 sq. mm. stranded wires?

    20 A

  • 73

    An accessory which serves to complete a conduit system, such as bushings and access fitting.

    Threaded connector

  • 74

    An accessory which serves to complete a conduit system, such as bushings and access fitting.

    Threaded connector