  • 1

    A component that appears in the 70 furnace but not a 90% furnace

    draft diverter

  • 2

    3 types of furnaces

    upflow downflow horizontal

  • 3

    An induced draft fan would be on a 70% furnace true or false

    False

  • 4

    Can a fan realy control a blower motor

    yes a relay can as well as a fan relay IFC

  • 5

    Four components required for a furnace

    limit switch thermostat fan switch Contactor

  • 6

    On a 90% furnace which portion of the exhaust gases condense

    secondary heat exchanger

  • 7

    What material should the venting of a 70% furnace be made of

    metal single wall

  • 8

    A device that Can reduce capacity of induced draft fan on a smaller furnace

    restrictor plate

  • 9

    What are the components gas flows through?

    gas valve manifold spud burner

  • 10

    Another term for exhaust

    flue pipe

  • 11

    What does the flue pipe Connect to

    chimney or outside

  • 12

    A heat anticipator can be adjusted to prevent

    thermostat overshoot

  • 13

    Which of the following three is? Measurement current flow

    amps

  • 14

    Which component forces air thought the heat exchanger inside the venting

    induced draft fan

  • 15

    Does a fan switch open or close when the furnace is hot

    Close when it’s hot open when it’s cool down

  • 16

    What would the jumper wire in the com/fan be removed

    The jumper will be removed when wire to 24 V

  • 17

    A transformer that uses 120v in the primary and 24v in secondary

    step down transformer

  • 18

    To adjust the speed on a Direct drive blower what device will be adjusted?

    relay

  • 19

    What are the components of a fan center?

    relay transformer junction box

  • 20

    What type of furnace produce water

    90% or plus

  • 21

    What does a 90% furnace require for condensation?

    collector box and drain line

  • 22

    Where does combustion take place on a 90%?

    Primary heat exchanger

  • 23

    What kind of limit switch it’s inside a blower motor

    auxiliary limit switch

  • 24

    What is the limit Switch used for

    to prevent extensive heat

  • 25

    What is the rollout switch for?

    release heat out the heat exchanger

  • 26

    What two pipes does a 90% efficiently furnace have

    intake pipe exhaust pipe

  • 27

    N/A

    N/a

  • 28

    N/a

    N/a

  • 29

    N/a

    n/a

  • 30

    What type of pipe is bi vent

    double wall pipe

  • 31

    What does IFC control

    Fan and ignition controls

  • 32

    How do you pinch a flue pipe

    upward pitch

  • 33

    Identify the switches

    temperature switch on rise and pressure switch open on the rise capacitor coil transformer

  • 34

    The part under the thermostat cover

    The subbase

  • 35

    What is the Y wire?

    blue for cooling

  • 36

    Is low-voltage such as 24V consider central voltage TRUE OR FLASE

    true

  • 37

    12 or red wire 24v is connected to what

    transformer secondary

  • 38

    What causes the open rollout switch

    crack in the heat exchanger

  • 39

    Where is a vent safety switch located on a 70% furnace

    draft diverter