暗記メーカー
ログイン
DOT 1 - write
  • kelly f

  • 問題数 90 • 9/3/2024

    記憶度

    完璧

    13

    覚えた

    33

    うろ覚え

    0

    苦手

    0

    未解答

    0

    アカウント登録して、解答結果を保存しよう

    問題一覧

  • 1

    An underground drainpipe that receives only subsurface or seepage water and convey it to a sump for disposal by gravity flow or by lift pump.

    subsoil drain

  • 2

    A loosely lined excavation in the ground. which receives the discharge of a septic tank and designed to permit the effluent from the septic tank to seep through pit bottom and sides.

    seepage pit

  • 3

    In sewerage, a common sewer to which no other branch sewer is connected. It receives sewage from building sewer service connections only.

    lateral

  • 4

    Wastes which require some special methods of handling such as the use of indirect waste piping and receptors; corrosion-resistant piping, sand, oil or grease interceptors; condensers or other pretreatment facilities.

    special wastes

  • 5

    ________ is the minimum cross-sectional area at the point of water supply discharge measured or expressed in terms of: (1) the diameter of a circle; (2) if the opening is not circular, the diameter of a circle of equivalent cross-sectional area. (This is applicable also to air gap installation.)

    effective opening

  • 6

    sometimes called a wash basin

    lavatory

  • 7

    This word, when used alone, shall mean these regulations, subsequent amendments thereto or any emergency rule or regulation which the Administrative Authority having jurisdiction may lawfully adopt.

    code

  • 8

    _____ are cast iron soil pipes with plain ends connected together with bolted stainless steel bands and neoprene gaskets.

    hubless pipes

  • 9

    It is any pipe or fitting installed in a horizontal position or which forms an angle of not more than forty-five (45) degrees with the horizontal plane.

    horizontal pipe

  • 10

    Includes all the pipings within public or private premises which convey sewage or other liquid wastes to a legal point of disposal but does not include the mains of a public sewer system or a public sewage treatment or disposal plant.

    drainage system

  • 11

    The vertical portion of a rainwater conductor

    downspout

  • 12

    Device or means to prevent the flow of liquid from returning to the source of supply. Also called a vacuum breaker

    backflow preventer

  • 13

    The flow of water or other liquids, mixtures, or substances into the distributing pipes of a potable supply of water from any source other than from its intended source

    backflow

  • 14

    The top edge of a receptacle from where water overflows.

    flood level rim

  • 15

    Any wastewater containing animal or vegetable matter in suspension or solution and may include liquids containing chemicals in solution

    sewage

  • 16

    It is an agency accepted by the Administrative Authority in the business of listing or labelling and which maintains a periodic inspection program on current production of listed models and makes available a published report of such listing where specific information is included tint the product has been tested against approved standards and found safe for use in a specific manner

    listing agency

  • 17

    A controlled outlet of a pipeline to discharge liquid or detritus.

    blow-off

  • 18

    An unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet conveying potable water to the flood-level rim of any tank, vat, or fixture

    air gap, water distribution

  • 19

    The part of a vent line, which connects directly with an individual trap underneath or behind the fixture and extends to the branch or main vent pipe at any point higher than the fixture or fixture traps it serves

    backvent pipe

  • 20

    A vertical opening through a building for elevators, dumbwaiters, lights. ventilation or similar purposes

    shaft

  • 21

    Also called a "sitz" bath.

    bidet

  • 22

    A return bend of a small-sized pipe, one end of which is about 30 cm. long and the other end is about 7.5 cm. long. It is commonly used as a faucet for a pantry sink. Also, the term means the flexible tubing connection between a service pipe and a water main

    gooseneck

  • 23

    The liquid and water-borne wastes derived from ordinary living processes, free from industrial wastes and of such character that permit satisfactory disposal without special treatment. It is discharged into the public sewer or into a private sewage disposal system.

    domestic sewage

  • 24

    Any pipe, which conveys the discharge of water closet, urinal or fixtures having similar functions, with or without the discharges from other fixtures to the building drain or building sewer.

    soil pipe

  • 25

    The Administrative Authority and includes any other law enforcement agency concerned by any provision of this Code, whether such agency is specifically named or not.

    Department Having Jurisdiction

  • 26

    Per Plumbing Code, PVC Drainpipes with toxic components are colored _____.

    brown grey orange

  • 27

    Whenever any work regulated by this Code is dangerous to human life or detrimental to health and property and Inadequate or unsafe water supply and or sewage disposal system.

    nuisance

  • 28

    An air pressure less than atmospheric. Also, implies siphonage in piping system

    vacuum

  • 29

    A room or space having a volume of less than 1.4 cu. m with 250 kilogram calorie of the aggregate input rating of all fuel-burning appliances installed in that space

    confined space

  • 30

    A sewer intended to receive sanitary sewage with or without pre-treated industrial wastes and without the admixture of rain or ground water.

    sanitary sewer

  • 31

    An open, unoccupied space, other than a court, unobstructed from the ground to the sky, except where specifically provided in this Code.

    yard

  • 32

    A valve located at the end of a water pipe through of which water can be drawn from or held within the pipe

    faucet

  • 33

    A person who specializes in the welding of pipes and holds a valid certificate of competency from a recognized testing agency, based on the requirements of the regulating authority

    pipeline welder

  • 34

    Building sewer begins ____ meters outside the building wall

    0.6

  • 35

    It is a device designed and installed to separate and retain deleterious, hazardous, or undesirable matters from normal wastes and permits normal sewage or liquid wastes to discharge into the disposal terminal by gravity

    interceptor (clarifier)

  • 36

    A drain connecting the compartments of a set of fixtures to a trap or connecting other permitted fixtures to a common trap

    continuous waste

  • 37

    A standpipe where water pressure is maintained at all times.

    wet standpipe

  • 38

    In a line of piping is a combination of elbows or bends, which brings one section of the pipe out of line but into a line parallel with the original section

    offset

  • 39

    _______ shall mean all buildings or structures that are not defined as private or private use

    public

  • 40

    Colored black. The cross-sectional shape is normally OVAL and is denoted by its O.D

    polybutylene (pb)

  • 41

    Not included in a Plumbing Unit floor drains - septic tank - faucets - water closet

    septic tank

  • 42

    That portion of a fixture drain between a trap and the vent

    trap arm

  • 43

    ______ are in-ground tanks designed to capture dirt, sand, to keep these substances out of our wastewater system.

    sand interceptor

  • 44

    It is an arbitrary quantity in terms of which the load-producing effects or water requirements on the plumbing system of different kinds of plumbing fixtures are expressed in some arbitrarily chosen scale. It is equivalent to a rate of flow at 28.3 liters per minute ( 1 cu. ft./minute)

    fixture unit

  • 45

    A room equipped with a shower stall or bathtub.

    bathroom

  • 46

    B&S means Brown and Sharpe (Specification) or ____ (Ends of Pipes)

    bell and spigot

  • 47

    A horizontal vent connecting one or more individual vertical back vents with the vent stack or stack vent

    branch vent

  • 48

    Minimum Branch Interval

    2.43

  • 49

    A branch vent that performs its functions for two (2) or more traps

    group vent

  • 50

    In plumbing, a secondary pipeline. In sewerage, a common sewer to which no other branch sewer is connected. It receives sewage from building sewer service connections only

    lateral

  • 51

    Grease interceptor min. capacity

    3 cu. m

  • 52

    The water supply pipe between the fixture supply pipe and the water-distributing pipe.

    fixture branch

  • 53

    Includes all valves and controls used in plumbing systems which are accessible

    regulating equipment

  • 54

    Are approved-type installed receptacles, devices, or appliances supplied with water or receive liquid or liquid-borne wastes and discharge such wastes into the drainage system to which they may be directly or indirectly connected. Industrial or commercial tanks, vats and similar processing equipment are not plumbing fixtures, but may be connected to or discharged into approved traps or plumbing fixtures as provided for in this Code

    plumbing fixtures

  • 55

    An impairment of the quality of potable water which creates an actual hazard to public health through poisoning or spread of disease by sewage, industrial fluids or waste. Also, defined as High Hazard

    contamination

  • 56

    It is a device, which discharges a predetermined quantity of water into fixtures for flushing purposes and is actuated by direct water pressure.

    flushometer valve

  • 57

    _____ is measured along its centerline.

    length of pipe

  • 58

    Combustible Construction is any structure which any part of its structural framework will ignite and burn at a temperature of _______

    756 degrees centigrade or less

  • 59

    A pipe, which conveys only wastewater or liquid waste, free of fecal matter

    waste pipe

  • 60

    An open, unoccupied space, bounded on two (2) or more sides by the walls of the building. An inner court is a court entirely within the exterior walls of a building

    court

  • 61

    A standpipe having no permanent water inside the pipe

    dry standpipe

  • 62

    That portion of a vent pipe through where wastewater also flows through.

    wet vent

  • 63

    Any part of the piping system other than a main, riser, or stack

    branch

  • 64

    A hose fitting with clapper valves for combining the flow from two or more lines of hose into a single stream. The inlet fitting of a fire standpipe located above ground level

    siamese connection

  • 65

    A building sewer, which receives the discharge from more than one building drain and conveys it to a public sewer, private sewage disposal system, or other points of disposal

    private sewer

  • 66

    A person technically and legally qualified and licensed to practice the profession of Master Plumbing without limitations in accordance with Republic Act 1378. having passed the examination conducted by the Professional Regulation Commission has received a Certificate of Registration from the Board of Master Plumbing and possessing the current license to practice

    master plumber

  • 67

    An unobstructed top open edge of a fixture

    rim

  • 68

    A receptacle in which liquids are retained for a sufficient period of time to allow settleable material to deposit

    catch basin

  • 69

    In Plumbing Code, referred to as "Low Hazard"

    pollution

  • 70

    This term means the flexible tubing connection between a service pipe and a water main

    gooseneck

  • 71

    Any one of a special class of device or equipment intended to perform a special plumbing function. Its operation and/or control may be dependent upon one or more energized components, such as motors, controls, heating elements and pressure-temperature-sensing elements. Such device or equipment may operate automatically through one or more of the following actions: a time cycle, a temperature range, a pressure range, a measured volume or weight; or the device or equipment may be manually adjusted or controlled by the user or operator

    plumbing appliance

  • 72

    _________ or street main is the water-supply pipe for public or community use

    water main

  • 73

    A tank located above or integral with a water closet, urinal, or similar fixtures for flushing or removing excrement in the fixture.

    flush tank

  • 74

    The pipe or tubing that connects the outlet of a plumbing fixture to the trap

    tailpiece

  • 75

    Part of the building drain that is the single sloping drain from the base of a stack to its junction with the main building drain.

    primary branch

  • 76

    Any public space, public park, or thoroughfare less than three (3) meters but not less than two (2) meters in width dedicated or deeded for public use. any public space. public park or thoroughfare less than three (3) meters but not less than two (2) meters in width dedicated or deeded for public use.

    alley

  • 77

    The pressure existing without any flow motion

    static pressure

  • 78

    Shall mean direct access without the necessity of removing any panel, door or similar obstruction

    readily accessible

  • 79

    The pipe carrying potable water from the water meter or other source of water supply to a building or other point of use or distribution on the lot. _____ shall also mean water service connection.

    building supply

  • 80

    Any and alI liquid or water-borne waste from industrial or commercial processes, except domestic sewage.

    industrial waste

  • 81

    The reconstruction or renewal of any part of an existing building for its maintenance

    repair

  • 82

    A cylindrical conduit or conductor conforming to the particular dimensions commonly known as “pipe size” and is denoted by its interior diameter or l.D.

    pipe

  • 83

    Supports, hangers, anchors, brackets, cradles are devices for holding and securing pipes and fixtures to walls, ceiling, floors or structural members

    supports

  • 84

    Pipes installed to provide flow of air to or from a drainage system or to provide a circulation of air within such system to protect traps seals from siphonage and back pressure

    vent system

  • 85

    A vertical shaft for the installation of different pipe stacks.

    chase

  • 86

    A building designed as a home by the owner of such building, and shall be the only dwelling located on a parcel of ground with the usual accessory building

    single family dwelling

  • 87

    Who establishes the Critical Level Marking on Backflow Prevention devices

    testing laboratory

  • 88

    A room space having a volume equal to at least 1.4 c.u. m. of the aggregate input rating of the fuel-burning appliance installed in that space. Rooms adjacent and open to the space where the appliance is installed, through openings not furnished with doors, are considered a part of the unconfined space

    unconfined space

  • 89

    It is the pipeline from the building to the public or street storm drainage system

    house storm sewer

  • 90

    A tool for straightening or bending lead pipe.

    bending pin (iron)