  • 1

    what is the name of a chemical substance that does not allow oxides to form on freshly cleaned copper before soldering or brazing

    flux

  • 2

    when a water supply system is tested with air the pressure applied is

    greater than the normal operating pressure

  • 3

    an escutcheon is used

    on the outside of the stub out

  • 4

    the trap seal is the maximum depth of a liquid that a trap will retian measured between the crown weir and

    the top of the dip of the trap

  • 5

    a vent connecting one or more individual vent stack is a

    branch vent

  • 6

    a pipe which makes an angle of 60 degrees with a horizontal is considered a

    vertical pipe

  • 7

    what type of joint is used in a durham system?

    screwed joint

  • 8

    a sewer line 50 feet long installed at a 2% grade will have a total fall of

    12 inches

  • 9

    a waste pipe that discharges into and through an approved open connection is called a/an

    indirect waste pipe

  • 10

    a ___________ type of faucet shall be included or installed to drain water from the bottom of water heaters

    boiler drain

  • 11

    what is the fall of a line of pipe if the run is 78 feet and the grade is 1/8" per foot

    9 3/4 inches

  • 12

    the approved standard for gas fired storage type water heaters is listed by

    ASME

  • 13

    the ____________ is located on all electric water heaters

    high limit control

  • 14

    before mechanical devices such a bulldozers grader etc, may be used for backfilling pipe trenches, the trench shall be backfilled in 6 inch layers to _________ above top crown of piping

    18 inches

  • 15

    piping and fixtures for which standards or specifications have not been adopted by code may be installed if

    approved by the illinois department of public health as an alternate

  • 16

    the minimum size cleanout allowed to serve a 4 inch drain line is

    4 inches

  • 17

    a horizontal drain pipe has an existing load of 30 drainage fixture units. after connecting the discharge pipe of a sewage ejector pump rate at 60 gpm the total load on the horizontal drain pipe will be

    150

  • 18

    the fitting that is required for making the yoke vent intersection with the drainage stack is a

    wye branch

  • 19

    the maximum developed length for an indirect water of any sanitary waste line shall not exceed

    5 feet

  • 20

    that portion of s fixture drain between a trap and its vent is called a

    trap arm

  • 21

    wall mounted water closets shall be securely bolted to

    a carrier fitting

  • 22

    the overflow pipe from a fixture shall be connected on the

    house or inlet side of the fixture trap

  • 23

    no shower or receptor for a single family house shall have a finished outside dimension which is less than

    32 inches

  • 24

    a material not listed in the code for use in potable water piping is

    aluminum

  • 25

    the term "solvent weld" apllies to

    plastic

  • 26

    tanks flushing more than one urinal shall be

    automatic in operation

  • 27

    the mathematical factor used by the plumbing industry to estimate the probable demand of each fixture shall be represented by

    fixture units

  • 28

    the maximum number of fixture units alloweed on a 4 inch sewer with a slope of 1/8 inch per foot as compared to a 4 inch sewer with a slope of 1/4 inch per foot is

    less

  • 29

    a valve which operates by screwing a disc against a seat is called

    globe valve

  • 30

    the maximum number of water closets on a three inch horizontal branch drain line is

    two

  • 31

    atmospheric type vacuum breakers shall not be subjected to

    back pressure

  • 32

    in a straight run underground drainage lines over 10 inches nominal diameter, manholes shall be provided and located at intervals of not more than

    150 feet

  • 33

    one of th following is not a standard fitting

    double hub

  • 34

    the maximum DFUs allowed on a two inch horizontal waste line

    6

  • 35

    which fitting may be installed in a horizontal drain line to receive waste

    double wye

  • 36

    the maximum temperature of any water discharging into any part of the drainage system is

    180 degrees

  • 37

    the minimum constant water service pressure on the dischrge side of the water meter shall be at least

    20 psi

  • 38

    of the following, the highest rate flow is

    1 gallon per secon

  • 39

    mechanical devices shall not be installed in the plumbing vent system except for single family structures where the homeowner is doing their own plumbing work.

    false

  • 40

    a combination waste and vent is permissible for floor drains only and then it must be for new construction only

    false

  • 41

    the 2004 illinois plumbing code permits a water closet to have 1 1/2 vent

    false

  • 42

    a galvanized pipe is a fitting with external threads used to close a pipe with internal threads

    false

  • 43

    a temperature and pressure relief valve shall discharge to the outside atmospher is a floor drain is not accessible

    false

  • 44

    a saddle is permissible ona potable water supply system when installing an ice maker or humidifier systems

    false

  • 45

    section 890 appendix a of the illinios plumbing code states that plastic water piping is acceptable for hot water distribution systems

    true

  • 46

    flared copper joints are permissible in an underground installation for water distribution within a building

    false