問題一覧
1
what is the name of a chemical substance that does not allow oxides to form on freshly cleaned copper before soldering or brazing
flux
2
when a water supply system is tested with air the pressure applied is
greater than the normal operating pressure
3
an escutcheon is used
on the outside of the stub out
4
the trap seal is the maximum depth of a liquid that a trap will retian measured between the crown weir and
the top of the dip of the trap
5
a vent connecting one or more individual vent stack is a
branch vent
6
a pipe which makes an angle of 60 degrees with a horizontal is considered a
vertical pipe
7
what type of joint is used in a durham system?
screwed joint
8
a sewer line 50 feet long installed at a 2% grade will have a total fall of
12 inches
9
a waste pipe that discharges into and through an approved open connection is called a/an
indirect waste pipe
10
a ___________ type of faucet shall be included or installed to drain water from the bottom of water heaters
boiler drain
11
what is the fall of a line of pipe if the run is 78 feet and the grade is 1/8" per foot
9 3/4 inches
12
the approved standard for gas fired storage type water heaters is listed by
ASME
13
the ____________ is located on all electric water heaters
high limit control
14
before mechanical devices such a bulldozers grader etc, may be used for backfilling pipe trenches, the trench shall be backfilled in 6 inch layers to _________ above top crown of piping
18 inches
15
piping and fixtures for which standards or specifications have not been adopted by code may be installed if
approved by the illinois department of public health as an alternate
16
the minimum size cleanout allowed to serve a 4 inch drain line is
4 inches
17
a horizontal drain pipe has an existing load of 30 drainage fixture units. after connecting the discharge pipe of a sewage ejector pump rate at 60 gpm the total load on the horizontal drain pipe will be
150
18
the fitting that is required for making the yoke vent intersection with the drainage stack is a
wye branch
19
the maximum developed length for an indirect water of any sanitary waste line shall not exceed
5 feet
20
that portion of s fixture drain between a trap and its vent is called a
trap arm
21
wall mounted water closets shall be securely bolted to
a carrier fitting
22
the overflow pipe from a fixture shall be connected on the
house or inlet side of the fixture trap
23
no shower or receptor for a single family house shall have a finished outside dimension which is less than
32 inches
24
a material not listed in the code for use in potable water piping is
aluminum
25
the term "solvent weld" apllies to
plastic
26
tanks flushing more than one urinal shall be
automatic in operation
27
the mathematical factor used by the plumbing industry to estimate the probable demand of each fixture shall be represented by
fixture units
28
the maximum number of fixture units alloweed on a 4 inch sewer with a slope of 1/8 inch per foot as compared to a 4 inch sewer with a slope of 1/4 inch per foot is
less
29
a valve which operates by screwing a disc against a seat is called
globe valve
30
the maximum number of water closets on a three inch horizontal branch drain line is
two
31
atmospheric type vacuum breakers shall not be subjected to
back pressure
32
in a straight run underground drainage lines over 10 inches nominal diameter, manholes shall be provided and located at intervals of not more than
150 feet
33
one of th following is not a standard fitting
double hub
34
the maximum DFUs allowed on a two inch horizontal waste line
6
35
which fitting may be installed in a horizontal drain line to receive waste
double wye
36
the maximum temperature of any water discharging into any part of the drainage system is
180 degrees
37
the minimum constant water service pressure on the dischrge side of the water meter shall be at least
20 psi
38
of the following, the highest rate flow is
1 gallon per secon
39
mechanical devices shall not be installed in the plumbing vent system except for single family structures where the homeowner is doing their own plumbing work.
false
40
a combination waste and vent is permissible for floor drains only and then it must be for new construction only
false
41
the 2004 illinois plumbing code permits a water closet to have 1 1/2 vent
false
42
a galvanized pipe is a fitting with external threads used to close a pipe with internal threads
false
43
a temperature and pressure relief valve shall discharge to the outside atmospher is a floor drain is not accessible
false
44
a saddle is permissible ona potable water supply system when installing an ice maker or humidifier systems
false
45
section 890 appendix a of the illinios plumbing code states that plastic water piping is acceptable for hot water distribution systems
true
46
flared copper joints are permissible in an underground installation for water distribution within a building
false