1
Hot air “FAULT” light illuminates on the air conditioning panel:
the hot air press reg. valve closes and the trim air valves close
2
In case of Air Conditioning System Controller dual lane failure:
the related Pack is lost, and the hot air pressure regulating valve and associated trim air valves closes.
3
During normal flight the Avionics Ventilation System controls the temperature of the cooling air by:
passing air through a skin heat exchanger
4
The RAM AIR switch should be used:
only when delta P is less than 1psi
5
Air Conditioning System Controller single lane failure:
no effect, as the second lane takes over
6
Each Pack is consist of heat exchangers, compressor and turbine. The purpose of the turbine is to:
drives the compressor, cooling air fan and also expands and cools the air.
7
The Mixer Unit connects to cabin fans, LP ground connector, emergency ram air inlet, Pack 1 and 2. The statement is:
True
8
Hot air press reg. valve failed open:
no effect
9
Bleed air supplied from the APU (APU bleed valve open), the pack flow is automatically selected to:
high
10
Trim air valve, each one optimizes the temperature by:
adding hot air
11
Hot air pressure regulating valve:
regulates the pressure of hot air, tapped upstream of the packs
12
Pack flow control valve:
pneumatically operated and electrically controlled
13
The temperature selectors are located in:
the cockpit overhead panel
14
Pack flow may be selected from:
the cockpit overhead panel
15
Engine flow demand, when the heating or cooling demand in one zone cannot be satisfied:
the minimum idle is increased automatically
16
What is the maximum norm cabin alt:
8000 ft
17
What is the maximum negative differential pressure for the cabin:
-1 psi
18
Is it possible to use simultaneously Packs and LP Ground Unit during long stops in a hot airfield:
no
19
Trim air valves are modulated by:
air conditioning system controllers
20
The mixing unit is connected to:
packs, cabin air, emergency ram air inlet and LP ground connector
21
Once set to “ON” the air conditioning packs operate:
automatically and independently of each other
22
Emergency ram air inlet, when set to “ON”, the ram air valve will open:
when delta P < 1 psi and the Ditching pb is not selected
23
Hot-Air Pressure-Regulating Valve is controlled by the:
Air Conditioning System Controller 1
24
Conditioned air is distributed to:
cockpit, forward and aft cabins
25
The cabin zone temperature sensors are ventilated by the air extracted by the lavatory and galleys fans:
True
26
Temperature control is automatic and is regulated by:
air conditioning system controllers
27
The Hot-Air Pressure-Regulating Valve closes automatically when:
either is correct
28
The Hot-Air Pressure-Regulating Valve closes automatically when:
cockpit trim air valve or cabin trim air valves fail
29
When the pack flow control selector is positioned to HI, air flow is:
120% of normal
30
When using APU bleed to supply the Packs, with the Pack Flow Selector at LO, the Pack air flow is:
120% of normal
31
The pack flow control valve closes automatically in case of:
pack overheat, engine fire push button released, engine start, ditching pb pressed
32
Trim air valve failure
the optimized temperature regulation of the corresponding zone is lost
33
There are how many trim air valves?
3 - one for the cockpit and two for the cabin
34
During landing run, packs ram air inlet flaps open when the speed is less than:
70 kts ( after 20 sec delay )
35
When APU is supplying the Packs, the air conditioning system controller sends a demand signal to increase air flow when a zone temperature cannot be satisfied:
to the APU ECB
36
The ditching switch when selected ON sends a closure signal to:
all are correct
37
In flight, with cabin pressure controller 1 in use, if it fails:
transfers automatically to cabin pressure controller 2
38
In normal operation, pressurization is:
fully automatic
39
The outflow valve is powered by:
one of three electric motors
40
During ground function operation, the outflow valve is:
fully opened
41
To see the position of the outflow valve, it is necessary to call ECAM:
CAB PRESS Page
42
Two identical, independent, automatic digital pressurization controllers are used for system control:
one controller active, one in standby
43
Which controller generates excess cabin altitude and pressure outputs for ECAM indication in manual mode:
N°1
44
When Ram Air pb is set to ON, the outflow valve will open 50% when delta P is:
< 1 psi
45
The purpose of the safety valves is to avoid:
both are correct
46
The safety valves are operated:
pneumatically
47
When landing elevation is set to AUTO, the landing elevation is sent to the controller from:
FMGC
48
When Mode SEL is set to MANUAL, the outflow valve is controlled by signals sent via controller 1 or 2:
False
49
On ECAM CAB PRESS page, the outflow valve indicator changes to amber if:
valve open (more than 95% during flight)
50
On ECAM CAB PRESS page, the safety valve indication changes to amber if:
one safety valve is open
51
On ECAM CAB PRESS page the cabin altitude indication changes to red, when the cabin altitude is:
> 9, 550 ft
52
Following a SYS 1 fault:
System 2 takes over automatically without crew action
53
Cabin pressurization starts at:
take-off power selection
54
The safety valves open at:
8.6 psi
55
In automatic mode, cabin pressurization is optimized by using information from:
FMGS landing field elev, dest. QNH and static pressure information
56
During normal flight and with skin temp. below + 35 °C, the avionics ventilation system controls the temperature of the cooling air by:
passing air through a skin heat exchanger
57
When the Ram Air pb set to “ON” the emer. ram air inlet valve will open:
when ∆P < 1 psi and ditching is not selected
58
The Residual Pressure Control Unit (RPCU) automatically depressurized the aircraft in case of abnormal residual pressure, it automatically opens the outflow valve when:
the OFV is not fully open + both CPCs fail + a/c on ground + all engines shutdown
59
When the RAM AIR pb is set to ON the outflow valve:
opens about 50% only when delta P is less than 1psi