記憶度
8問
24問
0問
0問
0問
アカウント登録して、解答結果を保存しよう
問題一覧
1
Pack flow may be selected from:
the cockpit overhead panel
2
Trim air valve failure
the optimized temperature regulation of the corresponding zone is lost
3
Trim air valves are modulated by:
air conditioning system controllers
4
Emergency ram air inlet, when set to “ON”, the ram air valve will open:
when delta P < 1 psi and the Ditching pb is not selected
5
The Hot-Air Pressure-Regulating Valve closes automatically when:
cockpit trim air valve or cabin trim air valves fail
6
During normal flight the Avionics Ventilation System controls the temperature of the cooling air by:
passing air through a skin heat exchanger
7
The safety valves are operated:
pneumatically
8
Temperature control is automatic and is regulated by:
air conditioning system controllers
9
Hot air pressure regulating valve:
regulates the pressure of hot air, tapped upstream of the packs
10
When the pack flow control selector is positioned to HI, air flow is:
120% of normal
11
When Ram Air pb is set to ON, the outflow valve will open 50% when delta P is:
< 1 psi
12
The cabin zone temperature sensors are ventilated by the air extracted by the lavatory and galleys fans:
True
13
In automatic mode, cabin pressurization is optimized by using information from:
FMGS landing field elev, dest. QNH and static pressure information
14
The temperature selectors are located in:
the cockpit overhead panel
15
On ECAM CAB PRESS page the cabin altitude indication changes to red, when the cabin altitude is:
> 9, 550 ft
16
In case of Air Conditioning System Controller dual lane failure:
the related Pack is lost, and the hot air pressure regulating valve and associated trim air valves closes.
17
Trim air valve, each one optimizes the temperature by:
adding hot air
18
Once set to “ON” the air conditioning packs operate:
automatically and independently of each other
19
There are how many trim air valves?
3 - one for the cockpit and two for the cabin
20
The Mixer Unit connects to cabin fans, LP ground connector, emergency ram air inlet, Pack 1 and 2. The statement is:
True
21
The mixing unit is connected to:
packs, cabin air, emergency ram air inlet and LP ground connector
22
During normal flight and with skin temp. below + 35 °C, the avionics ventilation system controls the temperature of the cooling air by:
passing air through a skin heat exchanger
23
When the Ram Air pb set to “ON” the emer. ram air inlet valve will open:
when ∆P < 1 psi and ditching is not selected
24
Following a SYS 1 fault:
System 2 takes over automatically without crew action
25
Hot air “FAULT” light illuminates on the air conditioning panel:
the hot air press reg. valve closes and the trim air valves close
26
The safety valves open at:
8.6 psi
27
Engine flow demand, when the heating or cooling demand in one zone cannot be satisfied:
the minimum idle is increased automatically
28
The RAM AIR switch should be used:
only when delta P is less than 1psi
29
During landing run, packs ram air inlet flaps open when the speed is less than:
70 kts ( after 20 sec delay )
30
Bleed air supplied from the APU (APU bleed valve open), the pack flow is automatically selected to:
high
31
Hot air press reg. valve failed open:
no effect
32
The pack flow control valve closes automatically in case of:
pack overheat, engine fire push button released, engine start, ditching pb pressed
33
The outflow valve is powered by:
one of three electric motors
34
Conditioned air is distributed to:
cockpit, forward and aft cabins
35
What is the maximum negative differential pressure for the cabin:
-1 psi
36
Each Pack is consist of heat exchangers, compressor and turbine. The purpose of the turbine is to:
drives the compressor, cooling air fan and also expands and cools the air.
37
Two identical, independent, automatic digital pressurization controllers are used for system control:
one controller active, one in standby
38
Hot-Air Pressure-Regulating Valve is controlled by the:
Air Conditioning System Controller 1
39
Cabin pressurization starts at:
take-off power selection
40
Is it possible to use simultaneously Packs and LP Ground Unit during long stops in a hot airfield:
no
41
To see the position of the outflow valve, it is necessary to call ECAM:
CAB PRESS Page
42
What is the maximum norm cabin alt:
8000 ft
43
During ground function operation, the outflow valve is:
fully opened
44
When the RAM AIR pb is set to ON the outflow valve:
opens about 50% only when delta P is less than 1psi
45
The Hot-Air Pressure-Regulating Valve closes automatically when:
either is correct
46
On ECAM CAB PRESS page, the safety valve indication changes to amber if:
one safety valve is open
47
Which controller generates excess cabin altitude and pressure outputs for ECAM indication in manual mode:
N°1
48
The purpose of the safety valves is to avoid:
both are correct
49
On ECAM CAB PRESS page, the outflow valve indicator changes to amber if:
valve open (more than 95% during flight)
50
When APU is supplying the Packs, the air conditioning system controller sends a demand signal to increase air flow when a zone temperature cannot be satisfied:
to the APU ECB
51
The Residual Pressure Control Unit (RPCU) automatically depressurized the aircraft in case of abnormal residual pressure, it automatically opens the outflow valve when:
the OFV is not fully open + both CPCs fail + a/c on ground + all engines shutdown
52
In normal operation, pressurization is:
fully automatic
53
Air Conditioning System Controller single lane failure:
no effect, as the second lane takes over
54
The ditching switch when selected ON sends a closure signal to:
all are correct
55
In flight, with cabin pressure controller 1 in use, if it fails:
transfers automatically to cabin pressure controller 2
56
When using APU bleed to supply the Packs, with the Pack Flow Selector at LO, the Pack air flow is:
120% of normal
57
Pack flow control valve:
pneumatically operated and electrically controlled
58
When landing elevation is set to AUTO, the landing elevation is sent to the controller from:
FMGC
59
When Mode SEL is set to MANUAL, the outflow valve is controlled by signals sent via controller 1 or 2:
False