暗記メーカー
ログイン
review
  • ユーザ名非公開

  • 問題数 40 • 5/4/2025

    記憶度

    完璧

    6

    覚えた

    14

    うろ覚え

    0

    苦手

    0

    未解答

    0

    アカウント登録して、解答結果を保存しよう

    問題一覧

  • 1

    What are the three fire fighting patterns

    D. Solid Stream, Narrow V, Wide V

  • 2

    ALPHA

    C. Paper, Wood

  • 3

    BRAVO

    D. JP-5,DMF, Fuel oil

  • 4

    Charlie

    A. Lightning Distribution Panel

  • 5

    DELTA

    B. Magnesium, Titanium

  • 6

    What are the 2 sizes of SCBA

    D. 30 MIN/45 MIN

  • 7

    Holes cut in the overhead for venting must be a minimum of?

    C. 12x12

  • 8

    What is the minimum number of personel Required to fully man a 1 1/2 Fire hose

    D. 3

  • 9

    What does PECU Stand For?

    C. Portable Exothermic cutting unit

  • 10

    What PPE should be worn when fighting

    B. ffe and scba

  • 11

    Scba’s are filled with what kind of air?

    B. Grade “D” Breathable Air

  • 12

    The box fan is rated at?

    B. 3200 cfm

  • 13

    What are the 2 sizes of vari nozzle used on board the Abraham Lincoln

    A. 95/125 gpm

  • 14

    If the team leader has a fully charged nimh battery how long?

    B. 4.85 Hours

  • 15

    What powers the ramfan

    A. Firemain

  • 16

    When Accessing a space, the hose team should be positioned

    D. Non-hinge side of the

  • 17

    To Prevent Electrical shock, What minimum distance and what pattern must be maintained by the nozzleman on the electrical components

    C. 4ft/FOG pattern

  • 18

    What are the two methods of attack when it comes to fighting a fire

    B. Direct/in-direct

  • 19

    What are the 5 stages of fire

    A. Incipient

  • 20

    Solid Stream

    B. Uses for overhaul and and breaking up materials

  • 21

    Narrow V

    C. Pushes towards flame front, normal firefighting

  • 22

    Wide V

    A. interrupts gasses in overhead

  • 23

    Rollover occurs during what stage of fire

    C. Growth

  • 24

    What report should be made right after an alpha fire is put out

    C. reflash watch set

  • 25

    The low air alarm on the scba sounds between 20-25% of air remaining. How many minutes of air is left once alarm sounds for 45 mins and 30 mins cylinders

    A. 9/6 min

  • 26

    Vari nozzles should be stowed on station in what pattern

    C. narrow V

  • 27

    The box fan is powered by

    D. 115V

  • 28

    When can a 1 1/2 firehouse be deployed and controlled by one person

    A. never

  • 29

    What is the minimum pressure allowed for an scba to be stowed in the locker

    D. 4000 psi

  • 30

    Who long should it take to don full fire fighting ensemble

    A. 2 1/2 - 5 mins

  • 31

    Personel endurance in a high heat environment while wearing the fee may be longer than?

    D. 10 mins

  • 32

    The ram fan is rated at?

    A. 2000 cmf

  • 33

    WHAT ARE AFFF IN-LINE EDUCTORS USED FOR?

    B. mixxing AFFF and firemain

  • 34

    TWO DIFFERENT HOSETEAMS ACCESSING FROM DIFFERENT ACCESS POINTS REQUIRES HOW MANY TEAM LEADERS?

    C. 2 team leader

  • 35

    What are the 2 modes of the nfti?

    B. Digital pyrometer/ video overlay

  • 36

    WHEN FIRST ATTACHING THE MASK MOUNTED REGULATOR TO THE SCBA MASK, WHERE SHOULD THE RED PURGE VALVE BE POINTING?

    b. STRAIGHT UP

  • 37

    37. WHO SHOULD THE TEAM LEADER CHECK IN WITH AFTER LEAVING THE REPAIR LOCKER, WHEN HEADING TO THE CASUALTY

    D. Scene Leader

  • 38

    Where does active Desmoking take place

    A. Smoke Control Zone

  • 39

    IF YOU WORE A GAS MASK INTO A FIRE SPACE, WHAT WOULD KILL YOU?

    d. ALL OF THE ABOVE

  • 40

    WHAT DOES NFTI STAND FOR?

    C. NAVAL FIREFIGHTING THERMAL IMAGER