暗記メーカー
ログイン
Diagnostic Exam 1
  • Jobeth Comandante

  • 問題数 100 • 9/29/2024

    記憶度

    完璧

    15

    覚えた

    35

    うろ覚え

    0

    苦手

    0

    未解答

    0

    アカウント登録して、解答結果を保存しよう

    問題一覧

  • 1

    Defines as settling down or separation of solid matter suspended in a liquid

    Sedimentation

  • 2

    An airtight receptacle used to expedite the decomposition of elements contained in a raw sewage

    Septic Tank

  • 3

    The lighter organic solid particles found in sewage, cesspools and septic tanks found floating on the liquid

    Scum

  • 4

    It is defined as the organic particles that have settled down in septic tank.

    Sludge

  • 5

    Minimum width of a septic tank for residential dwellings

    0.9 m

  • 6

    Minimum length of a septic tank for residential dwellings

    1.5 m

  • 7

    Minimum depth of a septic tank for residential dwellings

    0.6 m

  • 8

    Type of valve found on the service main, used to control the water service

    Corporation Stop

  • 9

    Type of valve used to prevent backflow or reversal of the flow of water

    Check Valve

  • 10

    Fitting used to describe the connection of the service pipe and water meter. Also used as the demarcation between the property of water service and water supply pipe system of the building

    union patente

  • 11

    Type of piping system that is characterized by threading and connecting cast iron pipes in the building

    Durham System

  • 12

    Type of pump used to distribute water within a building when an upfeed system cannot provide adequate pressure to supply the fixtures

    Pneumatic pump

  • 13

    Type of flushing valve used in commercial water closets, usually installed with a pressure tank that expels air pressure and a set amount of water when flushing

    Flushometer valve

  • 14

    Type of vent used in an island counter type kitchen sink

    Looped vent

  • 15

    Maximum vertical depth of liquid that trap can contain

    Trap seal

  • 16

    Vertical pipe that is used for the storage of water, usually contains pressure for fire suppression

    Standpipe

  • 17

    Type of pipe with 180 degree bend

    return bend

  • 18

    Water supply fixture unit of a bath tub in residential dwelling

    2

  • 19

    Water supply fixture unit of a shower in a resort

    4

  • 20

    A concrete sealed vault with a wooden shelter constructed for the collection of raw sewage

    Privy

  • 21

    Hole in the ground curbed with stones or bricks that allow raw sewage to leach in the ground

    Cesspool

  • 22

    Vent used for island sinks away from the wall

    Looped vent

  • 23

    System used to produce a more effective circulation of hot water to the upper floor levels of a multi-story building

    Pump Circuit System

  • 24

    Circulation of hot water by means of Mechanical Device

    Pump Circuit System

  • 25

    System where hot water rises on the highest point of the system and travels to the fixture via gravity

    Downfeed and Gravity Return System

  • 26

    A vent used to relieve the pressure ahead of moving effluent in a horizontal fixture branch

    Relief vent

  • 27

    A pipe connecting upward from a soil or waste stack to a vent stack for the purpose of preventing pressure changes in the stack

    Yoke vent

  • 28

    Yoke vent is required every

    5 floors

  • 29

    House sewer is part of the plumbing system which extends ____ from the foundation of the wall of the building

    0.6 meters

  • 30

    Lowest part of the inside face of any pipe

    Invert

  • 31

    Highest part of the inside of any pipe

    Crown

  • 32

    A part of a piping system other than main, riser, or stack

    Branch

  • 33

    A process used to make a water-tight or gas-tight seal in a joint using a mastic compound. It involves plugging an opening with oakum, lead, or other materials

    Caulking

  • 34

    Plumbing permit shall expire if the plumbing work is not commenced within

    365 days

  • 35

    It is a return bend of small-sized pipe, one end of which is about 30 cm long and the other end is about 7.5 cm long

    gooseneck

  • 36

    A receptacle designed to collect surface water or rainwater from a calculated open area

    Area drain

  • 37

    A drain that allows drainage through parapet wall

    Scupper drain

  • 38

    A conduit installed to remove water from the roof

    Roof drain

  • 39

    Part of a storm water drainage that collect storm water run-off and separate any debris or settleable matter

    Catch basin

  • 40

    The only flexible plastic tubing suitable for use with hot and cold water pressure

    Polybutylene (PB)

  • 41

    The oldest brand of Porcelain Kitchen Sink

    American Standard

  • 42

    It carries waste other than fecal matter

    Waste Drainage System

  • 43

    Which of the following is measured on its outside diameter?

    PPR

  • 44

    It checks or prevents reversal of flow

    Check valve

  • 45

    Commercial length of GI Pipe

    6 m

  • 46

    Minimum needed supply pressure for flushometer

    15 psi

  • 47

    Minimum needed supply pressure for flush tank

    8 psi

  • 48

    According to PNSDW, the recommended pH range for drinking water is

    6-8

  • 49

    Minimum distance between manholes

    300'

  • 50

    Horizontal drainage piping shall run at a uniform slope of not less than

    2 %

  • 51

    The maximum temperature of water discharging under pressure directly into the drainage system

    140 F

  • 52

    Closet bends or stubs shall be cut off so as to present a smooth surface even with the

    Top of the closet ring

  • 53

    Cast iron pipe shall not be joined by

    Brazing

  • 54

    The vertical distance between a fixture outlet and the trap weir shall not exceed

    24 in

  • 55

    Fixture trap shall have a liquid seal of not less than

    2 in

  • 56

    How many lavatories shall be installed in a elementary school with 240 male student

    7

  • 57

    What is the size of downspout if the rainfall intensity is 100mm if the deck roof is 435 sq.m.

    100 mm

  • 58

    Required when cast-iron pipe and fittings of different sizes are to be joined

    Increaser or Reducer

  • 59

    Except for the plastic pipe, in lieu of water test, drainage piping may be tested with

    air

  • 60

    With a few exception, all horizontal drainage piping shall be provided with a cleanout at

    its upper terminal

  • 61

    Clean-outs shall be designed to be

    gastight and watertight

  • 62

    Minimum size of fire hose outlet of an interior wet standpipe

    38 mm

  • 63

    What is the prescribed color coding of piping under Steam Division of a high pressure pipe?

    White

  • 64

    An oil tank is 3m long, 3m wide and 2m high, when it is full of coconut oil (sg = 0.90), find the downward force at the bottom of the tank.

    16,200 kg

  • 65

    Type of system used in plumbing that eliminates the vent stack, relying of downward pressure and suction

    Sovent System

  • 66

    Overhead tank water distribution system is a

    Gravity

  • 67

    Faucet normally turned 90 degrees to open or close

    Key cock

  • 68

    Type of connection found in a looped vent, connecting the looped vent pipe to the waste pipe

    Bleeder

  • 69

    A gate valve normally used to shut off flow of water from supply pipe.

    Shut off valve

  • 70

    Common problem in traps due to inadequate ventilation

    Trap seal loss

  • 71

    Type of vent that connects a battery of fixtures to a vent stack

    Circuit vent

  • 72

    Type of vent that connects a battery of fixtures to a stack vent

    Loop vent

  • 73

    Fitting screwed or caulked over the end of a pipe for closing pipe e

    Cap

  • 74

    A pipe which carries ground and surface waters, storm water or waste water

    Drain

  • 75

    Revised Fire Code of the Philippines of 2008

    RA 9514

  • 76

    Temperature at which water vapor forms above liquid fuel

    Flash point

  • 77

    It includes the discharge from latrine, urinals, bathroom, and kitchen

    Sewage

  • 78

    Applied to a specific disease when it normally prevails in locality and does not fluctuate markedly from the normal expected emergence of community

    Endemic

  • 79

    It is when the disease affects a large number of people at the same time and transcends community boundaries

    Pandemic

  • 80

    This applies to the occurrence of few scattered case of the disease

    Sporadic

  • 81

    Incidence of a communicable disease among a number of people that is recognized statistically as being well beyond the normal expectancy

    Epidemic

  • 82

    Minimum diameter of a house sewer

    6"

  • 83

    Class 1 type occupancy water supply

    Residence

  • 84

    Class 2 type occupancy water supply

    Restricted use

  • 85

    Class 3 type occupancy water supply

    Unrestricted use

  • 86

    Cause of objectionable tastes and odor of water

    Algae

  • 87

    Pipe from the street water main to the building served

    Service pipe

  • 88

    Pipe carrying potable water from the water meter to the building

    Building supply

  • 89

    Water supply connecting the fixture with the fixture branch

    Fixture supply

  • 90

    Vent installed so that one vent pipe serves two traps

    Unit vent

  • 91

    A pipe support used for a single run of pipe in vertical position

    Clamp

  • 92

    A pipe support used for multiple runs of pipe in horizontal position

    Bracket

  • 93

    Type of backflow prevention device approved for back pressure and back siphonage

    Double Check Valve

  • 94

    Noisiest type of water closest

    Washdown

  • 95

    Maximum length of nipple

    12"

  • 96

    Color code for pipeline used for electrical services

    Orange

  • 97

    Minimum weight of copper allowed to use for underground and above drainage and vent piping

    Type DWV

  • 98

    Maximum number of water closets for one vertical 3" soil pipe

    4

  • 99

    Maximum number of water closets for one horizontal 3" soil pipe

    3

  • 100

    1 psi is equivalent to a water head of

    2.31 ft