  • 1

    if you devide 16,744 and multiply the quotient by 47, the answer will be 34,216

    true

  • 2

    the pressure on the bottom of s tank of fluid varies directly with the density of the liquid in the tank

    true

  • 3

    a glove valve has very little resistance to flow

    false

  • 4

    clean out plugs may be used for the installation of a new plumbing fixture

    false

  • 5

    floor drains level with the floor shall discharge to sanitary waste drain

    true

  • 6

    a test tee at the base of the stack may be used as a cleanout

    true

  • 7

    a lavatory with a 1/4'' waste outlet shall be trapped with a 1 1/2'' trap

    false

  • 8

    a trap shall be installed in the building drain at a point approximately five feet outside the building foundation

    false

  • 9

    flow rate is measured as volume per unit of time

    true

  • 10

    a gallon of water (U.S standards) contains 231 cubic inches and weighs 8.345 pounds (avoirdupois) at maximum density and at normal temperature

    true

  • 11

    the air gap in a potable water supply system in the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank or plumbing fixture and the flood level rim of the recptacle

    true

  • 12

    the trap seal is the vertical distance between the crown weir and the top of the dip of the trap

    true

  • 13

    the invert is the floor , bottom, or the lowest part of the internal cross section of a pipe

    true

  • 14

    hot water is water at a temperature of not less than 120 degrees

    true

  • 15

    galvanized, aluminum, and stainless steel safe pans shall be at least 24 gauge

    true

  • 16

    polyethylene, polymer concrete and fiberglass materials are not acceptable for gas/oil interceptors

    false

  • 17

    poured concrete trench drains or poured concrete are approved for gas/oil interceptors

    false

  • 18

    hot and cold, tempered and cold, or tempered water only shall be supplied to all plumbing fixtures that are designed for hot and cold, tempered and cold, or tempered water

    true

  • 19

    bathtub lines/inserts shall be maufactured to an exact fit over existing bathtubs or costum fabricated according to the dimensions of an existing and shall have a slip resistance floor/bottom

    true

  • 20

    in schools that are not licensed by the illinios department of children and family services as day care centers or homes, water closets provided for the use of children under five years of age shall be of size and height suitable for childrens use, either child or juvenile type

    true

  • 21

    all self closing faucets located in public restrooms shall be adjusted to remain open for a minimum of 19 seconds and have 1.0 gpm flow restrictions

    false

  • 22

    facilities that do not have any employees working as attendants (business selling motor vehicle fuel to the public using automated machines) need not to have a restroom for public, employee, or maintenance staff

    false

  • 23

    the minimum depth for any water service shall be at least 36'' or at the maximum frost penetration of the local area, whichever is of greater depth

    true

  • 24

    the discharge piping shall discharge indirectly into a floor drain, hub drain, service sink, sump or a trapped and vented p-trap, which is located in the same room as the water heater, for all relief valves on water heaters

    true

  • 25

    reverse water flow in a water supply pipe caused by vacuum is called back siphonage

    true

  • 26

    the lowest piping of a drainage system which receives the discharge from soil, waste, and other drainage pipes, inside the walls of the building and conveys it to building sewer is called

    building drain

  • 27

    a magnesium rod is somtimes used in

    a storage type water heater

  • 28

    which of the following types of gasses is lighter than air

    natural gas

  • 29

    a peppermint test is used for testing

    the drainage system

  • 30

    where is the corporation stop located in a water service line

    at the tap in the water main

  • 31

    the small near the top end of a dip tube in a domestic water heater serves as a

    siphon breaker

  • 32

    a connection to the public sewer or private sewege diposal system is required for

    buildings with plumbing fixtures

  • 33

    piping, fixtures, or equipment which are installed so that it interferes with normal operation and use of windows or doors shal be

    relocated to avoid interference

  • 34

    cast iron pipe installed vertically shall be supported at not less than

    every story height

  • 35

    testing water piping shll be for a period of not less than

    15 min

  • 36

    the discharge capacity in gallons per minute for one unit is equal to

    7 1/2 gpm

  • 37

    the clearance required in front of a 2'' cleanout is not less than

    18''

  • 38

    the discharge line from S sanitary sewage ejector line shall be provided with a

    single check valve, gate valve, and a union

  • 39

    one factor for determining the size of a vent pipe is

    its length

  • 40

    all vent and branch lines shall be installed so as to drain back by gravity to

    the soil and waste pipe

  • 41

    the maximum developed length of the indirect waster of any sanitary waste line shall not exceed

    5 feet

  • 42

    the portion of a fixture drain between a trap and its vent called a

    trap arm

  • 43

    the distance between a water heater and the union on the water lines hall not be more than

    5 feet

  • 44

    no shower stall or receptor shall have a finished outside dimension which is less than

    32''

  • 45

    drinking fountains shall not be installed in

    toilet rooms

  • 46

    copper water tube type 'm' shall be installed within a building

    for the above ground use only

  • 47

    the available pressure at the water meter is 80psi at the highest supply outlet 36 feet above the water meter the pressure would be most nearly

    62 psi

  • 48

    atmospheric type vacuum breakers shallnot be subject to

    back pressure

  • 49

    the maximum number of fixture units allowed on a 4'' sewer with a slope of 1/8'' per foot, as compared to a 4'' sewer with a slop 1/4'' inch per foot is

    less

  • 50

    the total number of water closets on a 3 inch horizontal waste branch is

    2