問題一覧
1
if you devide 16,744 and multiply the quotient by 47, the answer will be 34,216
true
2
the pressure on the bottom of s tank of fluid varies directly with the density of the liquid in the tank
true
3
a glove valve has very little resistance to flow
false
4
clean out plugs may be used for the installation of a new plumbing fixture
false
5
floor drains level with the floor shall discharge to sanitary waste drain
true
6
a test tee at the base of the stack may be used as a cleanout
true
7
a lavatory with a 1/4'' waste outlet shall be trapped with a 1 1/2'' trap
false
8
a trap shall be installed in the building drain at a point approximately five feet outside the building foundation
false
9
flow rate is measured as volume per unit of time
true
10
a gallon of water (U.S standards) contains 231 cubic inches and weighs 8.345 pounds (avoirdupois) at maximum density and at normal temperature
true
11
the air gap in a potable water supply system in the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank or plumbing fixture and the flood level rim of the recptacle
true
12
the trap seal is the vertical distance between the crown weir and the top of the dip of the trap
true
13
the invert is the floor , bottom, or the lowest part of the internal cross section of a pipe
true
14
hot water is water at a temperature of not less than 120 degrees
true
15
galvanized, aluminum, and stainless steel safe pans shall be at least 24 gauge
true
16
polyethylene, polymer concrete and fiberglass materials are not acceptable for gas/oil interceptors
false
17
poured concrete trench drains or poured concrete are approved for gas/oil interceptors
false
18
hot and cold, tempered and cold, or tempered water only shall be supplied to all plumbing fixtures that are designed for hot and cold, tempered and cold, or tempered water
true
19
bathtub lines/inserts shall be maufactured to an exact fit over existing bathtubs or costum fabricated according to the dimensions of an existing and shall have a slip resistance floor/bottom
true
20
in schools that are not licensed by the illinios department of children and family services as day care centers or homes, water closets provided for the use of children under five years of age shall be of size and height suitable for childrens use, either child or juvenile type
true
21
all self closing faucets located in public restrooms shall be adjusted to remain open for a minimum of 19 seconds and have 1.0 gpm flow restrictions
false
22
facilities that do not have any employees working as attendants (business selling motor vehicle fuel to the public using automated machines) need not to have a restroom for public, employee, or maintenance staff
false
23
the minimum depth for any water service shall be at least 36'' or at the maximum frost penetration of the local area, whichever is of greater depth
true
24
the discharge piping shall discharge indirectly into a floor drain, hub drain, service sink, sump or a trapped and vented p-trap, which is located in the same room as the water heater, for all relief valves on water heaters
true
25
reverse water flow in a water supply pipe caused by vacuum is called back siphonage
true
26
the lowest piping of a drainage system which receives the discharge from soil, waste, and other drainage pipes, inside the walls of the building and conveys it to building sewer is called
building drain
27
a magnesium rod is somtimes used in
a storage type water heater
28
which of the following types of gasses is lighter than air
natural gas
29
a peppermint test is used for testing
the drainage system
30
where is the corporation stop located in a water service line
at the tap in the water main
31
the small near the top end of a dip tube in a domestic water heater serves as a
siphon breaker
32
a connection to the public sewer or private sewege diposal system is required for
buildings with plumbing fixtures
33
piping, fixtures, or equipment which are installed so that it interferes with normal operation and use of windows or doors shal be
relocated to avoid interference
34
cast iron pipe installed vertically shall be supported at not less than
every story height
35
testing water piping shll be for a period of not less than
15 min
36
the discharge capacity in gallons per minute for one unit is equal to
7 1/2 gpm
37
the clearance required in front of a 2'' cleanout is not less than
18''
38
the discharge line from S sanitary sewage ejector line shall be provided with a
single check valve, gate valve, and a union
39
one factor for determining the size of a vent pipe is
its length
40
all vent and branch lines shall be installed so as to drain back by gravity to
the soil and waste pipe
41
the maximum developed length of the indirect waster of any sanitary waste line shall not exceed
5 feet
42
the portion of a fixture drain between a trap and its vent called a
trap arm
43
the distance between a water heater and the union on the water lines hall not be more than
5 feet
44
no shower stall or receptor shall have a finished outside dimension which is less than
32''
45
drinking fountains shall not be installed in
toilet rooms
46
copper water tube type 'm' shall be installed within a building
for the above ground use only
47
the available pressure at the water meter is 80psi at the highest supply outlet 36 feet above the water meter the pressure would be most nearly
62 psi
48
atmospheric type vacuum breakers shallnot be subject to
back pressure
49
the maximum number of fixture units allowed on a 4'' sewer with a slope of 1/8'' per foot, as compared to a 4'' sewer with a slop 1/4'' inch per foot is
less
50
the total number of water closets on a 3 inch horizontal waste branch is
2