CDG- Plumbing Code 1
  • Lizy Tamayo

  • 問題数 48 • 11/21/2023

    記憶度

    完璧

    7

    覚えた

    18

    うろ覚え

    0

    苦手

    0

    未解答

    0

    アカウント登録して、解答結果を保存しよう

    問題一覧

  • 1

    Is measured along its centerline

    Length of pipe

  • 2

    A vertical vent connection on a horizontal soil or waste branch at a point downstream of the last fixture connection.

    Circuit vent

  • 3

    A septic tank with the effluent discharging into a subsurface disposal field, into one or more seepage pits or into a combination of subsurface disposal field and seepage pit or of such other facilities.

    Private sewage disposal system

  • 4

    It designed and constructed to retain solid, digest organic matter through a period of detention and to allow the liquid to discharge into the soil outside of the tank through seepage pit.

    Septic tank

  • 5

    A pressure less than atmospheric.

    Siphonage

  • 6

    Operates automatically by opening a hose valve.

    Automatic standpipe system

  • 7

    The vertical main of a system of soil, waste or vent pipings extending through one or more stories and extended thru the roof.

    Stack

  • 8

    The extension of a soil or waste stack above the highest horizontal drain connected to the stack.

    Stack vent

  • 9

    A tee with the branch to receive a threaded pipe or fittings.

    Tapped tee

  • 10

    Is the same as circuit vent except that it loops back and connect with a stack vent instead of a vent stack.

    Loop vent

  • 11

    Is the pipe from the water main or other source of water supply to the building served.

    Water service pipe

  • 12

    Cast iron pipe generally used for building installation.

    SV type

  • 13

    Cast iron pipe as extra duty pipe that generally used for underground installation.

    XV type

  • 14

    Can be used as soil, waste, ventilation and downspout where remarkably superior for embedment in concrete structure.

    Asbestos cement pipe

  • 15

    The cheapest among the sewer pipes sometimes recommended for house sewer and for septic tank installation.

    Bituminous fiber sewer pipe

  • 16

    It is made out of clay, cast into length of 75 cm treated with glazing compound and durable for underground installation.

    Vitrified clay pipe

  • 17

    Is made out from mild steel, drawn through a die and welded, cast into 6 m long. It deteriorate faster when used as hot water supply line.

    Galvanized steel pipe

  • 18

    Better in quality than the steel pipe for plumbing installation and more resistant to acid waste.

    Galvanized wrought iron pipe

  • 19

    Is used for a well-fitted hub connections.

    Cast iron standard pipe

  • 20

    Is preferred when a piece of pipe needed is shorter than 150 cm long. When the pipe is cut, both ends has hub to serve as joint connector.

    Cast iron double hub

  • 21

    The legality of RNPCP 1999 was based on what Section RA 1378?

    Section 4

  • 22

    Basic Principles listed in RNPCP 1999 was based on what section of RA 1378?

    Section 5

  • 23

    Is the use of Air Admittance Valve as an alternative of vent pipes a violation of Principle no.12 on our RNPCP 1999?

    Need Approval of Administrative Authority

  • 24

    When was the Board of Master Plumber Resolution No. 04 Series of 1999 that covered the Adoption and Promulgation of RNPCP 1999 approved?

    September 30, 1999

  • 25

    A permit is not required for the repairs that involve only ___.

    The working parts of faucets and valves

  • 26

    What is a DAO No. 34 Series 1990 all about?

    Revised Water Usage/Classification Water Quality Criteria

  • 27

    What is DAO No. 35 Series of 1990 all about?

    Revised Effluent Regulation of 1990

  • 28

    What is DOH Administrative Order No. 2007-0012 all about?

    Philippine National Standard for Drinking Water of 2007

  • 29

    According to Accessibility Law, the accessible toilet compartments shall have the following a minimum area of __?

    1.7 m x 1.8 m

  • 30

    According to Accessibility Law, a turning space of __ sqm. with a minimum dimension of __ mm for wheelchair users shall be provided outside water closet cubicles.

    2.25, 1500

  • 31

    According to Accessibility Law, a minimum of one accessible to persons with disabilities water closet in every floor for every ___ regular water closet.

    20

  • 32

    According to Accessibility Law, the maximum height of toilet seat for persons with disabilities is ___?

    450mm

  • 33

    According to Accessibility Law, the maximum height of lavatory for persons with disabilities is __?

    800mm

  • 34

    According to Accessibility Law, the urinals shall be of the wall-hung type and should have elongated lip; the maximum height of lip should be __ from the floor.

    480mm

  • 35

    In accordance with NBCP, how much be the plumbing fee for plumbing installation of a water closet in excess of one plumbing unit?

    Php 7.00

  • 36

    In accordance with NBCP, how much be the plumbing fee for plumbing installation of a shower head in excess of one plumbing unit?

    Php 2.00

  • 37

    In accordance with NBCP, how much be the plumbing fee for plumbing installation of a dental cupsidor?

    Php 4.00

  • 38

    In accordance with NBCP, how much be the plumbing fee for plumbing installation of a digestive chamber having 5 m3?

    Php 24.00

  • 39

    The minimum distance required between water supply wells and cesspool/seepage pit.

    45.7m

  • 40

    The minimum distance required between water supply wells and disposal fields.

    30.5m

  • 41

    The minimum distance required between water supply wells and building sewer.

    15.2

  • 42

    The minimum distance between seepage pit and cesspool.

    3.7m

  • 43

    The minimum distance pit/cesspool and septic tank.

    1.5m

  • 44

    The minimum distance pit/cesspool and disposal field.

    1.5m

  • 45

    The minimum distance between distribution box and disposal field?

    1.5m

  • 46

    The minimum distance between pressure public water main and septic tank.

    3.0m

  • 47

    The minimum distance between on site domestic water service line and building sewer.

    0.30m

  • 48

    The minimum distance between property line adjoining private property and seepage pit/cesspool.

    2.4m