Which of the following conditions will allow current to flow through a circuit?
a closed switch
2
For current to flow through a wiring system there must be:
all of the above
3
The voltage reading across an open switch of an energized electrical circuit should be:
the apppied voltage
4
The current required to operate a device rated for 1500 watts at 120 volts is:
12.5 amps
5
If a circuit is wired so that electrons can flow in only one possible path, the circuit is said to be a/an:
series circuit
6
In a parallel circuit containing a 3 ohm 2ohm 7ohm 8ohm and a 10ohm resistor, the current flow is:
highest through the 3 ohm resistor
7
With the fuse removed from the circuit, the resistance reading across a blown fuse will be:
infinity
8
Which of the following statements concerning electrical conductors is correct?
A junction box connector approved for the box and wire type must be used.
9
Equipment wiring diagrams indicate which of the following?
supply voltage, internal wiring, location of controls, field wiring
10
Equioment specifications indicate mainlv:
dimensions required to install the appliance, weight of the equipment, electrical characteristics, size and location of the vent outlet, piping inlet size, model number
11
The word "symptom" is used in manufacturers' literature to describe:
abnormal operation of the equipment
12
A "bill of materials" is a:
list indicating the materials required to complete an installation
13
To correct a symptom such as a fluctuating flame, a technician should first:
consult the manufacturer's instructions
14
If the scale on a mechanical drawing is 1/8" - 1'0" then a line measuring 4" in length is actually:
32 feet
15
Mechanical drawings are used to
give the building address, show the equipment location, piping layout, duct sizing and duct layout
16
Equipment service bulletins are normally issued by the:
manufacturer
17
On a roof with a 10/12 pitch, and a wall 4 feet high and 6 feet away from the vent opening, what is the minimum vent height for a category one propane-fired appliance?
6 feet
18
On a roof with a 12/12 pitch and no obstructions, the minimum vent height for a natural gas fired appliance is:
4 feet
19
The B149.1-05 Code is used to determine:
requirements for installing gas appliances
20
Venting and air supply requirements are in section_____of the b149.1 code
8
21
All furnace appliance manufacturers' literature gives the name of the manufacturer, the:
Btuh input, fan size, CFM, voltage, fuse size, and the physical dimensions
22
A broken or dotted line on a manufacturer's wiring diagram normally indicates:
field installed wiring
23
Safety directives and bulletins are issued by the:
Technical Standards and Safety Authority
24
If a 1/2 cubic foot test dial makes one complete revolution in 18 seconds, the input is:
100k BTU
25
If the appliance manual shut off valve is in the closed position, movement of the 1/2 cu. ft. test dial indicates:
a gas leak in the line downstream from the gas meter
26
The diameter of a drip or dirt pocket shall be equal to the diameter of the piping or tubing that it serves. or
2 inch
27
Steel piping used in gas installations shall comply with:
ASTM A53 or ASTM A106
28
If a branch piping outlet is installed in the main supply piping before it is known what size of piping is going to be connected to it, what size should the outlet be?
the same size as the main supply piping
29
The fittings used to protect pipe threads during shipment are not allowed to be used in installations because they:
are made with running threads
30
For a piping system supplying an appliance having a rated input under 400,000 Btuh (120 kW), the supply line and branch line to the appliance may be purged:
at a readily accessible burner such as the open top burner of a gas range.
31
Which of the following statements is correct?
Close nipples shall not be used in gas piping systems.
32
What is the maximum horizontal spacing of supports for NPS 1 1/4 inch gas pipe in a home?
10 feet (3m)
33
Hose used to connect the propane supply to a domestic water heater shall.
not be permitted
34
What is the maximum allowable length of corrugated flexible connector when it is used to connect a suspended appliance to piping or tubing?
2 feet (600mm)
35
No one may initially activate a 300,000 Btu input appliance connected to a piping system:
unless the installation is inspected by a G.2 technician or higher
36
An orifice for a propane appliance with the same input as a natural gas appliance is:
smaller than the natural gas orifice
37
Boilers transfer heat to water through:
conduction
38
A recessed wall furnace may use which of the following?
a BW vent
39
The purpose of a burner in a forced air furnace is to:
mix the air and gas
40
An indication of excessive primar air is a:
lifting flame
41
Infrared heaters may not be used in:
occupied residencies
42
If the gas / air velocity is too great at the port of an atmospheric burner, the flame will have a tendency to:
life off the port
43
An appliance which incorporates a glow bar has a_______ ignition system
hot surface
44
Most underfired storage water heater temperature controls utilize:
rod and tube sensors
45
The configuration of a "Hi Boy" forced air gas furnace has:
supply air exiting at the top and return air entering at the bottom
46
if the return and supply air plenum are both located on the top of the furnace, the furnace is a°
low boy
47
A surface combustion infrared heater requires:
no vent
48
The purpose of the high limit switch found on many gas-fired appliances is to:
shut off the main gas valve should overheating occur.
49
What is TEMPERATURE RISE in a forced warm air furnace?
the temperature difference between the supply air and the return air
50
Conduction is:
the transfer of heat from particle to particle
51
Decorative appliances to be installed in vented fireplaces mounted on a grating system - are usually referred to as
gas logs
52
Infrared and tube heaters transfer heat by.
radiation
53
Gas piping requirements are in section_______ of the B149.1-05 code.
6
54
The required pipe size for section 'E' of the main supply line is
2”
55
The required pipe size for section 'G' of the main supply line is:
2”
56
The required pipe size for section 'K' of the main supply line is:
1 1/2”
57
The required pipe size for section 'B' of the sub-supply line is:
1 1/2”
58
The required pipe size for the branch lines supplying the unit heaters is:
1”
59
The required pipe size for sections 'D' and 'M' supplying the boilers is:
1 1/4”
60
The required pipe size for the branch line supplying the duct furnace is:
1 1/4”