PLUMBING CODE
  • christinejoy dawa

  • 問題数 33 • 3/11/2024

    記憶度

    完璧

    4

    覚えた

    14

    うろ覚え

    0

    苦手

    0

    未解答

    0

    アカウント登録して、解答結果を保存しよう

    問題一覧

  • 1

    A _____ may be installed with indirect waste.

    Grease

  • 2

    Because of structural conditions, a 4-inch house drain is installed with a slope of 1/8 inch per foot. This installation will result in a (an) ____________.

    reduction in fixture unit loading allowance

  • 3

    A ________ may be installed with indirect waste

    drinking fountain

  • 4

    A seamless drawn-brass fixture tailpiece shall be __________.

    20 B&S gauge

  • 5

    Water heater vents terminate above a roof surface at least __________ froma vertical wall.

    12 inches

  • 6

    The distance from the center of a water closet to any side wall or partitions shall not be closet than ________.

    15 inches

  • 7

    Drinking fountains may be installed with

    indirect wastes

  • 8

    Joints at the roof around pipes shall be made watertights by the use of

    flashings

  • 9

    A device to prevent backflow into the potable water system is called a

    backflow preventer

  • 10

    That portion on a venting system that connects a water heater to a vent is a

    vent connector

  • 11

    The minimum size waste pipe for a residential kitchen sink is ________.

    2 inches

  • 12

    Each drainage stack that extends 10 or more stories above the building drain shall be served by _______.

    a parallel vent stack

  • 13

    The minimum common horizontal waste pipe serving a bathtub, a lavatory, and a kitchen sink shall be at least _______.

    2 inches

  • 14

    What kind of joint is not allowed in cast iron pipe?

    threaded

  • 15

    The tailpiece for a lavatory shall not be less than _______.

    1-1/4 inch

  • 16

    Unless serving sinks or urinals, cleanouts may be omitted on a horizontal drain line that is

    less than 1.5 meters

  • 17

    The sizing of gas vents for category II, III, and IV shall be in accordance with ________.

    the manufacturers instructions

  • 18

    When sizing a copper fuel-gas piping system that has an inlet pressure of less than 2 psi with a pressure drop of 0.3 inch w.c., the maximum cubic feet per hour of gas flow allowed through a 5/8 - inch O.D. ACR tube 75 feet in developed length is ________ .

    27

  • 19

    The maximum length for a 1-1/2 - inch vent pipe is _______ .

    60 feet

  • 20

    What is the minimum age requirement for an appointee to become a member of the Board of Master Plumbers?

    Thirty years old

  • 21

    The minimum horizontal distance between a water supply well and the building sewer is ____________ .

    50 feet

  • 22

    Soil and drain pipes located above food-handling establishments shall be subjected to a standing water test of not less than ______ feet.

    10

  • 23

    A vent in a combination waste and vent system shall be approximately equal in area to one-half the ___________ .

    cross-sectional of the drain pipe served

  • 24

    Concealed slip joint connection require a (an) _________.

    12 x 12 access panel

  • 25

    The minimum size trap and trap arm for a kitchen sink is ________.

    1-1/2 inches

  • 26

    Single-wall metal pipe shall be constructed of ______ not less than 0.0304 inch thick.

    galvanized, sheet steel

  • 27

    Nonmetallic shower sub-pans or linings may be built up on the job site of not less than ___________.

    three layers of 15 pound felt

  • 28

    The required clearance in front of a 3-inch cleanout is __________.

    18 inches

  • 29

    Ferrous gas piping installed underground in exterior locations shall have at least _________.

    1 foot of earth cover

  • 30

    The minimum clearance of listed appliances to any combustible wall or partitions is _________.

    specified in listing or rating plate and NFPA 211 Standard

  • 31

    Leaks in gas piping shall be located by applying ________.

    soapy water to the exterior of the pipping

  • 32

    A noncorrosive leak detection fluid

    approved for use at least 12 inches belowground

  • 33

    Sheet metal, constituting a part of any vent connector, shall be at least ________.

    0.0304 inches