  • 1

    1. A type of diagram that use in designing or troubleshooting electrical installation control equipment so arrangement to simplify the tracing of the circuit?

    B. Schematic diagram

  • 2

    2. Which the following electrical parameter apply or labeled to all kind of switch

    C. Rated current and rated voltage

  • 3

    3. When tightening a terminal screw connection with the splice wire, the end to the splice wire should pass around the screw in the same direction as the screw is turned, so that_______.

    C. The will not turn off

  • 4

    4. One most advantage of using rubber insulation tape in splice is______.

    C. Does not absorb much moisture

  • 5

    5. A mechanical device such as locknut, bushing or connectors intended primarily for a mechanical rather than an electrical function.

    B. Fittings

  • 6

    6. What is the commonly use conduit in service entrance?

    D. RSC/IMC

  • 7

    7. What is the type of fitting commonly used for exposed conduit support.

    A. Conduit strap/clamp

  • 8

    8. The box use for convenience outlet.

    D. Utility box

  • 9

    9. A mechanical connector that is crimped unto a conductor for both splice and termination is known as.

    C. Mechanical lug

  • 10

    10. Commonly used adhesive materials for joining of PVC conduit.

    B. PVC solvent

  • 11

    11. The size of circuit breaker to be used in 40 a motor full load current is

    D. Equal to 100at

  • 12

    12. A live duplex wire can be de-energized quickly and safely by cutting

    D. One by one using diagonal cuter

  • 13

    13. When measuring load current, an ammeter is connected____.

    B. In series with the load

  • 14

    14. When measuring load resistance, the ohmmeter is connected_______.

    C. Across the terminal of the load

  • 15

    15. What is the ampacity of # 8.0 sq.mm.Thw wires?

    C. 25 amperes

  • 16

    16. What will you do if the load schedule reflects a 20at/2.0 sq. Mm. Lighting branch circuit of which circuit breaker is over rated?

    C. Look for the wiring layout and cheek for groupings

  • 17

    17. What amount of current will be drawn by incandescent bulb connected to a 115-volt circuit if its resistant is 268.5 ohms

    B. 0.43 amperes

  • 18

    18. When measuring ballast resistance if it is defective or good, it is necessary that the source

    B. De-energized

  • 19

    19. A circuit is an electrical protective device which_______.

    B. Protects electrical equipment from current surge and overload

  • 20

    20. It is the connection between the grounded circuit conductor and the equipment grounding conductor at the service conductor

    C. Bonding jumper, main

  • 21

    21. Which of the following is an output device

    D. Magnetic lock

  • 22

    22. The technical term for the thw wires used mostly in industrial wirings is

    A. Pvc insulated heat resistance

  • 23

    23. Which of the following is the input device

    D. All of the above

  • 24

    24. When skinning a small wire, the insulation should be “pencil down” rather that cut square to

    D. Decrease danger of nicking the wire

  • 25

    25. The minimum size of the conduit commonly used in laying-out of auxiliary devices

    B. ¾ “ diameter

  • 26

    26. An electrician should have his tools in good condition, the most important reason being is_____.

    D. Defective tools can cause accident and damage to equipment

  • 27

    27. What type of hand tools commonly used in boring of ½ “diameter hole in a panel board

    C. Knock out puncher and adjustable wrench

  • 28

    28. A mechanical device such as lock nut, bushing or connector intended primarily for a mechanical rather than an electrical function

    B. Fittings

  • 29

    29. What are the type of fitting commonly used for tightening between the boxes and the conduit

    A. Straight connector

  • 30

    30. The box use for typical switches

    D. Utility box