ログイン

FIRE CODE

FIRE CODE
47問 • 2年前
  • Angelica Miranda
  • 通報

    問題一覧

  • 1

    what is the fire code of the philippines?

    RA 9514

  • 2

    what is the old fire code of the philippines?

    PD 1185

  • 3

    any act that would remove or neutralize a fire hazard

    abatement

  • 4

    an integrated piping system connected to a source of extinguishing agent which suppresses fires when actuated by its automatic detecting device

    automatic fire suppression system

  • 5

    the head of the city fire station or the municipal fire station

    fire marshall

  • 6

    a wall designed to prevent the spread of fire

    firewall

  • 7

    what is the resistance rating of a firewall according to fire code of the philippines?

    not less than 4 hours

  • 8

    a continuous and unobstructed route of exit from one point in a building to a public way

    means of egress

  • 9

    the purpose of which a building or space is used

    occupancy

  • 10

    buildings 15 m or more in height

    high rise building

  • 11

    the maximum number of persons that may be allowed to occupy a particular building or space

    occupant load

  • 12

    a building that is unsafe in case of fire because it will burn easily or because it lacks adequate exits

    fire trap

  • 13

    what is the meaning of FALAR?

    fire and life safety assessment report

  • 14

    documentation on safety features of the facility prepared by the architect

    FALAR 1

  • 15

    documentation submitted by contractor or construction management certifying that construction was in accordance with FALAR 1

    FALAR 2

  • 16

    what is the meaning of FSEC

    fire safety evaluation clearance

  • 17

    what is the meaning of FSIC?

    fire safety inspection certificate

  • 18

    building permit 1. you need an FSEC, so you need your plans to be reviewed 2. you need a building plan review so you prepare FALAR 1 along with other requirements 3. you need a building permit so you need an FSEC

    3, 1, 2

  • 19

    occupancy permit 1. you are done with construction so you need an occupancy permit 2. you need an FSIC so you need an inspection 3. you need an occupancy permit so you need an FSIC 4. you want them to release FSIC after inspection so you prepare FALAR 2

    1, 3, 2, 4

  • 20

    business permit 1. you need to get/the new a business permit so you need an FSIC 2. you need an FSIC so you need an inspection 3. you want them to release the FSIC after inspection so you prepare FALAR 3

    1, 2, 3

  • 21

    RA 9514 rows of seats back to back

    830 mm

  • 22

    RA 9514 at least ___ from back of one seat to font of the next seat

    300mm

  • 23

    RA 9514 seats between aisles

    14 maximum

  • 24

    RA 9514 seats between wall and aisle

    7 maximum

  • 25

    RA 9514 seats without arms

    600 mm per person

  • 26

    travel distance to exit without sprinkler system

    46 m

  • 27

    travel distance to exit with sprinkler system

    61 m

  • 28

    RA 9514 minimum corridor width

    1120 mm

  • 29

    occupant load concentrated use without fixed seats such as places of worship dance floors

    0.65 sqm/person

  • 30

    occupant load less concentrated use such as conference room dining rooms and gym

    1.40 sqm/person

  • 31

    occupant load standing rooms/waiting space

    0.28 sqm/person

  • 32

    wet stand pipes - all portions of the building must be within ___ meters of a nozzle attached to a 22 m long hose

    6

  • 33

    what is the minimum diameter of a wet stand pipes according to RA 9514?

    64 mm

  • 34

    it required a wet stand pipes if the assembly occupancies with at least ___ occupant load

    1,000

  • 35

    it required a wet stand pipes for school hospital businesses hotels or ___ Storeys or taller

    4

  • 36

    you need a wet stand pipes for hazardous occupancies exceeding ____ per floor

    1,860

  • 37

    buildings with ____ is exempted to have a wet stand pipes

    approved sprinkler system

  • 38

    notifies occupance of the building in when required emergency forces, department notification

    fire alarms

  • 39

    it is not allowed as fire escape or means of egress

    ladders

  • 40

    standard handrails from a first surface of thread RA 9514

    760mm-865mm

  • 41

    minimum headroom RA 9514

    2.00 meters

  • 42

    RA 9514 Door clear opening

    710mm-1220mm

  • 43

    RA 9514 door max threshold height

    13mm

  • 44

    travel distance to EXITS for individual rooms with maximum occupant load of 6

    15 meters

  • 45

    RA 9514 number of exceeds for 0-499 occupant load

    2 exits

  • 46

    RA 9514 number of exits for 500 to 1,000 occupant load

    3 exits

  • 47

    number of exits for 1,000 or more occupant load

    4 exits

  • TROPICAL DESIGN

    TROPICAL DESIGN

    Angelica Miranda · 5問 · 2年前

    TROPICAL DESIGN

    TROPICAL DESIGN

    5問 • 2年前
    Angelica Miranda

    STRUCTURAL CONCEPTS

    STRUCTURAL CONCEPTS

    Angelica Miranda · 15問 · 2年前

    STRUCTURAL CONCEPTS

    STRUCTURAL CONCEPTS

    15問 • 2年前
    Angelica Miranda

    STRUCTURAL CONCEPTUALIZATION 1

    STRUCTURAL CONCEPTUALIZATION 1

    Angelica Miranda · 12問 · 2年前

    STRUCTURAL CONCEPTUALIZATION 1

    STRUCTURAL CONCEPTUALIZATION 1

    12問 • 2年前
    Angelica Miranda

    DICTUMS

    DICTUMS

    Angelica Miranda · 28問 · 2年前

    DICTUMS

    DICTUMS

    28問 • 2年前
    Angelica Miranda

    PROFESSIONAL PRACTICE

    PROFESSIONAL PRACTICE

    Angelica Miranda · 47問 · 2年前

    PROFESSIONAL PRACTICE

    PROFESSIONAL PRACTICE

    47問 • 2年前
    Angelica Miranda

    PROFESSIONAL PRACTICE SET 2

    PROFESSIONAL PRACTICE SET 2

    Angelica Miranda · 25問 · 2年前

    PROFESSIONAL PRACTICE SET 2

    PROFESSIONAL PRACTICE SET 2

    25問 • 2年前
    Angelica Miranda

    PROFESSIONAL PRACTICE SET 3

    PROFESSIONAL PRACTICE SET 3

    Angelica Miranda · 19問 · 2年前

    PROFESSIONAL PRACTICE SET 3

    PROFESSIONAL PRACTICE SET 3

    19問 • 2年前
    Angelica Miranda

    PLANNING

    PLANNING

    Angelica Miranda · 13問 · 2年前

    PLANNING

    PLANNING

    13問 • 2年前
    Angelica Miranda

    PLANNING HISTORY

    PLANNING HISTORY

    Angelica Miranda · 31問 · 2年前

    PLANNING HISTORY

    PLANNING HISTORY

    31問 • 2年前
    Angelica Miranda

    DEFECTS ON TIMBER

    DEFECTS ON TIMBER

    Angelica Miranda · 14問 · 2年前

    DEFECTS ON TIMBER

    DEFECTS ON TIMBER

    14問 • 2年前
    Angelica Miranda

    DEFECTS ON TIMBER PICTURE

    DEFECTS ON TIMBER PICTURE

    Angelica Miranda · 14問 · 2年前

    DEFECTS ON TIMBER PICTURE

    DEFECTS ON TIMBER PICTURE

    14問 • 2年前
    Angelica Miranda

    RPF GROUPS

    RPF GROUPS

    Angelica Miranda · 98問 · 2年前

    RPF GROUPS

    RPF GROUPS

    98問 • 2年前
    Angelica Miranda

    BUILDING MATERIALS 1 PICTURES

    BUILDING MATERIALS 1 PICTURES

    Angelica Miranda · 33問 · 2年前

    BUILDING MATERIALS 1 PICTURES

    BUILDING MATERIALS 1 PICTURES

    33問 • 2年前
    Angelica Miranda

    BM STONE WORK & BRICKS PICTURES

    BM STONE WORK & BRICKS PICTURES

    Angelica Miranda · 44問 · 2年前

    BM STONE WORK & BRICKS PICTURES

    BM STONE WORK & BRICKS PICTURES

    44問 • 2年前
    Angelica Miranda

    BM WOODS AND SCREW PICTURES

    BM WOODS AND SCREW PICTURES

    Angelica Miranda · 19問 · 2年前

    BM WOODS AND SCREW PICTURES

    BM WOODS AND SCREW PICTURES

    19問 • 2年前
    Angelica Miranda

    BM SURFACE FINISHES

    BM SURFACE FINISHES

    Angelica Miranda · 22問 · 2年前

    BM SURFACE FINISHES

    BM SURFACE FINISHES

    22問 • 2年前
    Angelica Miranda

    BM SHRINKAGE OF CONCRETE & TEMPERATURE CHANGES

    BM SHRINKAGE OF CONCRETE & TEMPERATURE CHANGES

    Angelica Miranda · 11問 · 2年前

    BM SHRINKAGE OF CONCRETE & TEMPERATURE CHANGES

    BM SHRINKAGE OF CONCRETE & TEMPERATURE CHANGES

    11問 • 2年前
    Angelica Miranda

    GLASS FITTINGS/ACCESSORIES 1

    GLASS FITTINGS/ACCESSORIES 1

    Angelica Miranda · 5問 · 2年前

    GLASS FITTINGS/ACCESSORIES 1

    GLASS FITTINGS/ACCESSORIES 1

    5問 • 2年前
    Angelica Miranda

    BOLTS NUTS AND WASHER PICTURES

    BOLTS NUTS AND WASHER PICTURES

    Angelica Miranda · 45問 · 2年前

    BOLTS NUTS AND WASHER PICTURES

    BOLTS NUTS AND WASHER PICTURES

    45問 • 2年前
    Angelica Miranda

    NAILS

    NAILS

    Angelica Miranda · 48問 · 2年前

    NAILS

    NAILS

    48問 • 2年前
    Angelica Miranda

    SCREWS

    SCREWS

    Angelica Miranda · 39問 · 2年前

    SCREWS

    SCREWS

    39問 • 2年前
    Angelica Miranda

    DOOR HARDWARE

    DOOR HARDWARE

    Angelica Miranda · 67問 · 2年前

    DOOR HARDWARE

    DOOR HARDWARE

    67問 • 2年前
    Angelica Miranda

    CABINET LOCK

    CABINET LOCK

    Angelica Miranda · 8問 · 2年前

    CABINET LOCK

    CABINET LOCK

    8問 • 2年前
    Angelica Miranda

    SHELF SUPPORT

    SHELF SUPPORT

    Angelica Miranda · 12問 · 2年前

    SHELF SUPPORT

    SHELF SUPPORT

    12問 • 2年前
    Angelica Miranda

    DOOR ACCESSORIES/HARDWARE

    DOOR ACCESSORIES/HARDWARE

    Angelica Miranda · 23問 · 2年前

    DOOR ACCESSORIES/HARDWARE

    DOOR ACCESSORIES/HARDWARE

    23問 • 2年前
    Angelica Miranda

    HOA ISLAMIC STRUCTURE

    HOA ISLAMIC STRUCTURE

    Angelica Miranda · 23問 · 2年前

    HOA ISLAMIC STRUCTURE

    HOA ISLAMIC STRUCTURE

    23問 • 2年前
    Angelica Miranda

    HOA ROMANESQUE

    HOA ROMANESQUE

    Angelica Miranda · 31問 · 2年前

    HOA ROMANESQUE

    HOA ROMANESQUE

    31問 • 2年前
    Angelica Miranda

    HOA GOTHIC

    HOA GOTHIC

    Angelica Miranda · 46問 · 2年前

    HOA GOTHIC

    HOA GOTHIC

    46問 • 2年前
    Angelica Miranda

    HOA RENAISSANCE, JACOBIAN & PALLADIANISM

    HOA RENAISSANCE, JACOBIAN & PALLADIANISM

    Angelica Miranda · 46問 · 2年前

    HOA RENAISSANCE, JACOBIAN & PALLADIANISM

    HOA RENAISSANCE, JACOBIAN & PALLADIANISM

    46問 • 2年前
    Angelica Miranda

    HOA BAROQUE & ROCOCO

    HOA BAROQUE & ROCOCO

    Angelica Miranda · 16問 · 2年前

    HOA BAROQUE & ROCOCO

    HOA BAROQUE & ROCOCO

    16問 • 2年前
    Angelica Miranda

    HOA DESCRIPTIVE QUESTIONS

    HOA DESCRIPTIVE QUESTIONS

    Angelica Miranda · 5問 · 2年前

    HOA DESCRIPTIVE QUESTIONS

    HOA DESCRIPTIVE QUESTIONS

    5問 • 2年前
    Angelica Miranda

    BL BP344

    BL BP344

    Angelica Miranda · 84問 · 2年前

    BL BP344

    BL BP344

    84問 • 2年前
    Angelica Miranda

    BL BP 344 MIN MAX

    BL BP 344 MIN MAX

    Angelica Miranda · 69問 · 2年前

    BL BP 344 MIN MAX

    BL BP 344 MIN MAX

    69問 • 2年前
    Angelica Miranda

    NATIONAL BUILDING CODE

    NATIONAL BUILDING CODE

    Angelica Miranda · 48問 · 2年前

    NATIONAL BUILDING CODE

    NATIONAL BUILDING CODE

    48問 • 2年前
    Angelica Miranda

    BU PUMPS

    BU PUMPS

    Angelica Miranda · 24問 · 2年前

    BU PUMPS

    BU PUMPS

    24問 • 2年前
    Angelica Miranda

    BU CABLE

    BU CABLE

    Angelica Miranda · 27問 · 2年前

    BU CABLE

    BU CABLE

    27問 • 2年前
    Angelica Miranda

    BU GENSETS

    BU GENSETS

    Angelica Miranda · 6問 · 2年前

    BU GENSETS

    BU GENSETS

    6問 • 2年前
    Angelica Miranda

    BU ELECTRICAL

    BU ELECTRICAL

    Angelica Miranda · 13問 · 2年前

    BU ELECTRICAL

    BU ELECTRICAL

    13問 • 2年前
    Angelica Miranda

    BU STANDARD PLUGS

    BU STANDARD PLUGS

    Angelica Miranda · 13問 · 2年前

    BU STANDARD PLUGS

    BU STANDARD PLUGS

    13問 • 2年前
    Angelica Miranda

    BU VALVES

    BU VALVES

    Angelica Miranda · 19問 · 2年前

    BU VALVES

    BU VALVES

    19問 • 2年前
    Angelica Miranda

    BU NIPPLES

    BU NIPPLES

    Angelica Miranda · 5問 · 2年前

    BU NIPPLES

    BU NIPPLES

    5問 • 2年前
    Angelica Miranda

    BU SWITCHES

    BU SWITCHES

    Angelica Miranda · 21問 · 2年前

    BU SWITCHES

    BU SWITCHES

    21問 • 2年前
    Angelica Miranda

    BU FITTINGS PLASTIC

    BU FITTINGS PLASTIC

    Angelica Miranda · 28問 · 2年前

    BU FITTINGS PLASTIC

    BU FITTINGS PLASTIC

    28問 • 2年前
    Angelica Miranda

    WHEELED EQUIPMENT

    WHEELED EQUIPMENT

    Angelica Miranda · 13問 · 2年前

    WHEELED EQUIPMENT

    WHEELED EQUIPMENT

    13問 • 2年前
    Angelica Miranda

    BU ACU/COOLER

    BU ACU/COOLER

    Angelica Miranda · 10問 · 2年前

    BU ACU/COOLER

    BU ACU/COOLER

    10問 • 2年前
    Angelica Miranda

    BU CCTV

    BU CCTV

    Angelica Miranda · 9問 · 2年前

    BU CCTV

    BU CCTV

    9問 • 2年前
    Angelica Miranda

    BU WATER SOURCE, STORAGE SUPPLY

    BU WATER SOURCE, STORAGE SUPPLY

    Angelica Miranda · 15問 · 2年前

    BU WATER SOURCE, STORAGE SUPPLY

    BU WATER SOURCE, STORAGE SUPPLY

    15問 • 2年前
    Angelica Miranda

    BU WATER DISTRIBUTION

    BU WATER DISTRIBUTION

    Angelica Miranda · 15問 · 2年前

    BU WATER DISTRIBUTION

    BU WATER DISTRIBUTION

    15問 • 2年前
    Angelica Miranda

    BU PLUMBING ROUGHING IN & FIXTURES PIPES, FITTING, JOINTINGS

    BU PLUMBING ROUGHING IN & FIXTURES PIPES, FITTING, JOINTINGS

    Angelica Miranda · 20問 · 2年前

    BU PLUMBING ROUGHING IN & FIXTURES PIPES, FITTING, JOINTINGS

    BU PLUMBING ROUGHING IN & FIXTURES PIPES, FITTING, JOINTINGS

    20問 • 2年前
    Angelica Miranda

    BU PLUMBING FIXTURES

    BU PLUMBING FIXTURES

    Angelica Miranda · 20問 · 2年前

    BU PLUMBING FIXTURES

    BU PLUMBING FIXTURES

    20問 • 2年前
    Angelica Miranda

    BU DRAINAGE SYSTEM

    BU DRAINAGE SYSTEM

    Angelica Miranda · 20問 · 2年前

    BU DRAINAGE SYSTEM

    BU DRAINAGE SYSTEM

    20問 • 2年前
    Angelica Miranda

    BU WASTE DISPOSAL TREATMENT and RECYCLING

    BU WASTE DISPOSAL TREATMENT and RECYCLING

    Angelica Miranda · 20問 · 2年前

    BU WASTE DISPOSAL TREATMENT and RECYCLING

    BU WASTE DISPOSAL TREATMENT and RECYCLING

    20問 • 2年前
    Angelica Miranda

    BU PRINCIPLES OF ELECTRICITY

    BU PRINCIPLES OF ELECTRICITY

    Angelica Miranda · 15問 · 2年前

    BU PRINCIPLES OF ELECTRICITY

    BU PRINCIPLES OF ELECTRICITY

    15問 • 2年前
    Angelica Miranda

    BU SYSTEM COMPONENTS OF BUILDING

    BU SYSTEM COMPONENTS OF BUILDING

    Angelica Miranda · 15問 · 2年前

    BU SYSTEM COMPONENTS OF BUILDING

    BU SYSTEM COMPONENTS OF BUILDING

    15問 • 2年前
    Angelica Miranda

    BU WIRES AND CABLES

    BU WIRES AND CABLES

    Angelica Miranda · 15問 · 2年前

    BU WIRES AND CABLES

    BU WIRES AND CABLES

    15問 • 2年前
    Angelica Miranda

    BU BULB

    BU BULB

    Angelica Miranda · 7問 · 2年前

    BU BULB

    BU BULB

    7問 • 2年前
    Angelica Miranda

    BU JOINING PIPES

    BU JOINING PIPES

    Angelica Miranda · 10問 · 2年前

    BU JOINING PIPES

    BU JOINING PIPES

    10問 • 2年前
    Angelica Miranda

    BL ARCH LAWS, REGULATORY & ENF, DESIGN & CONSTRUCTION

    BL ARCH LAWS, REGULATORY & ENF, DESIGN & CONSTRUCTION

    Angelica Miranda · 18問 · 2年前

    BL ARCH LAWS, REGULATORY & ENF, DESIGN & CONSTRUCTION

    BL ARCH LAWS, REGULATORY & ENF, DESIGN & CONSTRUCTION

    18問 • 2年前
    Angelica Miranda

    LAW DATES

    LAW DATES

    Angelica Miranda · 18問 · 2年前

    LAW DATES

    LAW DATES

    18問 • 2年前
    Angelica Miranda

    BU STEEL FITTINGS

    BU STEEL FITTINGS

    Angelica Miranda · 19問 · 2年前

    BU STEEL FITTINGS

    BU STEEL FITTINGS

    19問 • 2年前
    Angelica Miranda

    BU VENT

    BU VENT

    Angelica Miranda · 6問 · 2年前

    BU VENT

    BU VENT

    6問 • 2年前
    Angelica Miranda

    BU FLUSHING, URINAL, BATHTUB

    BU FLUSHING, URINAL, BATHTUB

    Angelica Miranda · 15問 · 2年前

    BU FLUSHING, URINAL, BATHTUB

    BU FLUSHING, URINAL, BATHTUB

    15問 • 2年前
    Angelica Miranda

    BU TRAP, DRAIN

    BU TRAP, DRAIN

    Angelica Miranda · 12問 · 2年前

    BU TRAP, DRAIN

    BU TRAP, DRAIN

    12問 • 2年前
    Angelica Miranda

    RANDOM COLOR

    RANDOM COLOR

    Angelica Miranda · 10問 · 2年前

    RANDOM COLOR

    RANDOM COLOR

    10問 • 2年前
    Angelica Miranda

    RANDOM ROOF

    RANDOM ROOF

    Angelica Miranda · 20問 · 2年前

    RANDOM ROOF

    RANDOM ROOF

    20問 • 2年前
    Angelica Miranda

    BL HOUSING, PLUMBING

    BL HOUSING, PLUMBING

    Angelica Miranda · 14問 · 2年前

    BL HOUSING, PLUMBING

    BL HOUSING, PLUMBING

    14問 • 2年前
    Angelica Miranda

    RANDOM JOINERY

    RANDOM JOINERY

    Angelica Miranda · 57問 · 2年前

    RANDOM JOINERY

    RANDOM JOINERY

    57問 • 2年前
    Angelica Miranda

    BL ENVIRONMENT, GOV SERVICES AND ETHICS LAW

    BL ENVIRONMENT, GOV SERVICES AND ETHICS LAW

    Angelica Miranda · 13問 · 2年前

    BL ENVIRONMENT, GOV SERVICES AND ETHICS LAW

    BL ENVIRONMENT, GOV SERVICES AND ETHICS LAW

    13問 • 2年前
    Angelica Miranda

    RANDOM VERNACULAR TERMS

    RANDOM VERNACULAR TERMS

    Angelica Miranda · 59問 · 2年前

    RANDOM VERNACULAR TERMS

    RANDOM VERNACULAR TERMS

    59問 • 2年前
    Angelica Miranda

    問題一覧

  • 1

    what is the fire code of the philippines?

    RA 9514

  • 2

    what is the old fire code of the philippines?

    PD 1185

  • 3

    any act that would remove or neutralize a fire hazard

    abatement

  • 4

    an integrated piping system connected to a source of extinguishing agent which suppresses fires when actuated by its automatic detecting device

    automatic fire suppression system

  • 5

    the head of the city fire station or the municipal fire station

    fire marshall

  • 6

    a wall designed to prevent the spread of fire

    firewall

  • 7

    what is the resistance rating of a firewall according to fire code of the philippines?

    not less than 4 hours

  • 8

    a continuous and unobstructed route of exit from one point in a building to a public way

    means of egress

  • 9

    the purpose of which a building or space is used

    occupancy

  • 10

    buildings 15 m or more in height

    high rise building

  • 11

    the maximum number of persons that may be allowed to occupy a particular building or space

    occupant load

  • 12

    a building that is unsafe in case of fire because it will burn easily or because it lacks adequate exits

    fire trap

  • 13

    what is the meaning of FALAR?

    fire and life safety assessment report

  • 14

    documentation on safety features of the facility prepared by the architect

    FALAR 1

  • 15

    documentation submitted by contractor or construction management certifying that construction was in accordance with FALAR 1

    FALAR 2

  • 16

    what is the meaning of FSEC

    fire safety evaluation clearance

  • 17

    what is the meaning of FSIC?

    fire safety inspection certificate

  • 18

    building permit 1. you need an FSEC, so you need your plans to be reviewed 2. you need a building plan review so you prepare FALAR 1 along with other requirements 3. you need a building permit so you need an FSEC

    3, 1, 2

  • 19

    occupancy permit 1. you are done with construction so you need an occupancy permit 2. you need an FSIC so you need an inspection 3. you need an occupancy permit so you need an FSIC 4. you want them to release FSIC after inspection so you prepare FALAR 2

    1, 3, 2, 4

  • 20

    business permit 1. you need to get/the new a business permit so you need an FSIC 2. you need an FSIC so you need an inspection 3. you want them to release the FSIC after inspection so you prepare FALAR 3

    1, 2, 3

  • 21

    RA 9514 rows of seats back to back

    830 mm

  • 22

    RA 9514 at least ___ from back of one seat to font of the next seat

    300mm

  • 23

    RA 9514 seats between aisles

    14 maximum

  • 24

    RA 9514 seats between wall and aisle

    7 maximum

  • 25

    RA 9514 seats without arms

    600 mm per person

  • 26

    travel distance to exit without sprinkler system

    46 m

  • 27

    travel distance to exit with sprinkler system

    61 m

  • 28

    RA 9514 minimum corridor width

    1120 mm

  • 29

    occupant load concentrated use without fixed seats such as places of worship dance floors

    0.65 sqm/person

  • 30

    occupant load less concentrated use such as conference room dining rooms and gym

    1.40 sqm/person

  • 31

    occupant load standing rooms/waiting space

    0.28 sqm/person

  • 32

    wet stand pipes - all portions of the building must be within ___ meters of a nozzle attached to a 22 m long hose

    6

  • 33

    what is the minimum diameter of a wet stand pipes according to RA 9514?

    64 mm

  • 34

    it required a wet stand pipes if the assembly occupancies with at least ___ occupant load

    1,000

  • 35

    it required a wet stand pipes for school hospital businesses hotels or ___ Storeys or taller

    4

  • 36

    you need a wet stand pipes for hazardous occupancies exceeding ____ per floor

    1,860

  • 37

    buildings with ____ is exempted to have a wet stand pipes

    approved sprinkler system

  • 38

    notifies occupance of the building in when required emergency forces, department notification

    fire alarms

  • 39

    it is not allowed as fire escape or means of egress

    ladders

  • 40

    standard handrails from a first surface of thread RA 9514

    760mm-865mm

  • 41

    minimum headroom RA 9514

    2.00 meters

  • 42

    RA 9514 Door clear opening

    710mm-1220mm

  • 43

    RA 9514 door max threshold height

    13mm

  • 44

    travel distance to EXITS for individual rooms with maximum occupant load of 6

    15 meters

  • 45

    RA 9514 number of exceeds for 0-499 occupant load

    2 exits

  • 46

    RA 9514 number of exits for 500 to 1,000 occupant load

    3 exits

  • 47

    number of exits for 1,000 or more occupant load

    4 exits