troubleshooting
  • ユーザ名非公開

  • 問題数 49 • 6/8/2024

    記憶度

    完璧

    7

    覚えた

    19

    うろ覚え

    0

    苦手

    0

    未解答

    0

    アカウント登録して、解答結果を保存しよう

    問題一覧

  • 1

    What kind meter reading indicate an open relay coil

    infinite ohms

  • 2

    What is the first 120 volt load you see running a call for neat?

    induced draft fan

  • 3

    What is the first switch to close on a call for heat

    thermostat

  • 4

    What cause high temperature rise

    clogged coil

  • 5

    What is a symptom on a block drain on a 90% furnace?

    Open pressure switch

  • 6

    What can cause the limit switch to open

    dirty filter dirty coil

  • 7

    What meter readings will indicate a short circuit when checking resistance of a motor

    0 ohms

  • 8

    What is switching action of a heating thermostat

    open on a rise

  • 9

    What does infinite Resisance across the switch mean

    open switch

  • 10

    What is the symptom of short to ground?

    blown fuse

  • 11

    Power must be off and a load must be isolated to test

    resistance

  • 12

    If there’s 120 V to the induced draft fan and the motor doesn’t start, you should?

    replace the motor

  • 13

    If there’s 0 volts from R to C but 24v at secondary what is wrong

    Open limit switch

  • 14

    If there’s 24v from W to C and the induced draft fan Doesn’t start what’s wrong

    induce draft fan relay has failed

  • 15

    When measuring heat to neutral What is being tested?

    Low speed blower motor

  • 16

    If we have 24V R to C and 0 Volts W to C what is wrong?

    failed thermostat

  • 17

    What could be wrong if the transformer primary has 0 V

    Open motor door/ interlock door switch

  • 18

    If the pressure switch is open an induced draft fan running what is wrong

    blockage in the venting

  • 19

    If the limit switch is open What could be the cause

    high gas pressure

  • 20

    What meter reading can indicate open limit switch?

    24V across / infinite ohms / outgoing Side to common

  • 21

    What are you do if you see bees

    spray them

  • 22

    What happens after the inducer motor start

    pressure switch closes

  • 23

    What conducts Electricity to ground from The flame sensor when the burner light

    Flame

  • 24

    What is the typical igniter voltage

    120v

  • 25

    What is the symptom of loose ground wire to IFC?

    burner light and then shuts off

  • 26

    IDF relay closes

    before burners ignite

  • 27

    Call for heat

    before pressure switch closes

  • 28

    IDF relay closes

    Before motor starts or pre-purge

  • 29

    Blower on delay

    before blower off delay and T stat closes

  • 30

    120v to ?

    Transformer primary

  • 31

    What is the symptom of a dirty A coil?

    Open limit switch

  • 32

    What is the symptom of a plugged drain on a 90%

    Open pressure switch

  • 33

    What is the symptom of a faulty t-stat

    reading 0 from w to c

  • 34

    Which of the following is a symptom of an open induce draft fan motor winding

    B

  • 35

    Which of the following symptoms of an Open blower motor winding

    Open limit switch

  • 36

    Where is rollout switch located?

    near the burners

  • 37

    Where is the auxiliary switch located

    blower compartment

  • 38

    What does the pressure switch connect to

    induced draft fan housing

  • 39

    Where is the IFC located?

    blower compartment

  • 40

    Where is the flame sensor located?

    near the burners

  • 41

    What could be wrong if there’s high temperature rise

    High temperature rise

  • 42

    What is the manifold pressure in a natural gas furnace

    3.5 inches of water column

  • 43

    What switch would be open if the flue pipe is blocked

    pressure switch

  • 44

    What tool is used to measure gas pressure?

    manometer

  • 45

    What could cause an Open rollout switch

    crack in the heat exchanger

  • 46

    What winding of a blower Motor has the highest resistance

    short winding

  • 47

    What is the minimum resistance or a hermetic motor winding to ground

    1 million ohms 1 mega ohms

  • 48

    If we’re measuring a compressor from run to start what does that mean?

    open winding

  • 49

    What type of load is a motor

    inductive load